Technical data CCT L

From pubWiki-en
Revision as of 10:54, 29 October 2010 by Grzegorzg (Talk | contribs) (Parametry techniczne)

Jump to: navigation, search

Technical parameters

  • power supply 230VAC, 50Hz,
  • power consumption max. 120 VA (for all PABX ports occupation),
  • protection against overcurrents and overvoltage from telecommunication network,
  • analogue internal ports with pulse and tone (DTMF) dialing,
  • full functionality for phones with DTMF,
  • CLIP signaling: internal and transfered to external lines,
  • CLIP receiving in FSK system on analogue trunks,
  • configurable ISDN BRA 2B+D ports (terminals ISDN S/T),
  • ports of analogue trunks,
  • terminals:

- ISDN 2B+D – DSS1 protocol (EURO – ISDN), - ISDN 30B+D – DSS1 protocol (EURO – ISDN), - analogue external trunks, according ASS signaling, - GSM – Dual Band: GSM 900, GSM 1800, - VoIP – via LAN, WAN interfaces- according SIP, IAX protocols, (codecs: GSM, G.711a/μ, G.729), - Up0 – digital terminals for system phones CTS-202.CL, CTS-202.BT.

  • Interfejsy:

- LAN, WAN – Ethernet 10/100 Mbps,

- RS-232,

- USB 2.0.

  • obsługa telefonów cyfrowych ISDN z sygnalizacją DSS1,
  • PABX ambient temperature: +5oC÷+35oC,
  • air humidity: 40÷70%,
  • fulfiling directives for CE sign obtaining :

- LVD,

- EMC,

- R&TTE.