Difference between revisions of "MSB-1102 Instruction manual"
From pubWiki-en
(→Certificate of conformity, proper device disposal) |
(→Certificate of conformity, proper equipement disposal) |
||
Line 52: | Line 52: | ||
{{warning|It is not allowed to direct controlling with 230VAC voltage. For this purpose, appropriate external relays, connected to 2REL socket should be used.}} | {{warning|It is not allowed to direct controlling with 230VAC voltage. For this purpose, appropriate external relays, connected to 2REL socket should be used.}} | ||
− | =[[MSB | + | =[[MSB Certificate of conformity |Certificate of conformity, proper equipement disposal]]= |
---- | ---- | ||
{{References}} | {{References}} |
Latest revision as of 10:53, 10 January 2011
Contents
Information
Slican Multi Switch Box MSB-1102 it is device assuring cooperation between Slican PABX[1] and sensors, relays, alarm systems, paging systems etc.
Subscriber port in PABX should be configured as Sensor or Relay – depending on required function.
MSB-1102 Structure
MSB-1102 is equipped with following input/output ports:
- sockets AB1/AB2 type RJ11 for connecting 2 subscriber ports in PABX,
- socket 2REL[2] (REL1/REL2) type RJ45 which includes:
- sensor terminals (SNS1/SNS2) – configurable,
- monostable relay terminals[3] – configurable,
- socket ZAS – local power supply from external source.
Connecting and preparing for configuration
Configuration Jumpers
|
Operating modes
Power supply | Sensors (SNS) | Relays (REL) |
---|---|---|
Without power supply | ||
With power supply |
According above table MSB-1102 must be supplied from local power supply device in following operating modes:
- Sensors: CCS mode
- Relays: VON/VOFF mode
Parameters
- current downloaded from power supply unit in CCS mode - max. 20mA.
- current downloaded in DCI mode - max.10mA per sensor.
- relay terminal parameters (for NO/NC and VON/VOFF modes) - max 42VAC/0.5A, 42VDC/1A
- Sensor activate voltage range - DCI and CCS modes - 5-30V[4]DC.
|
Certificate of conformity, proper equipement disposal
References
- ↑ MSB-1102 can be used with firmware version 4.10 or later. It can be used with Slican PABXes: CXS-0424, CCT-1668, MAC-Zero, MAC-6400.
- ↑ Device uses 2 independent channels. It means that simultaneously two functions can operate. Ex: 2 sensors, 2 relays or mix.
- ↑ Release pulse time is about 1 second.
- ↑ Attention: Polarity is important