Difference between revisions of "User:Grzegorzg"
(→Programming options) |
(→Programming options) |
||
Line 423: | Line 423: | ||
This field has information meaning and depends on jumper location on CONFIG terminal (allowed value are from ''0..15''). Every cassette number must be unique if there are few doorphones in the system. | This field has information meaning and depends on jumper location on CONFIG terminal (allowed value are from ''0..15''). Every cassette number must be unique if there are few doorphones in the system. | ||
|- | |- | ||
− | |'''P12'''||'''<nowiki>[4321]</nowiki><ref name=" | + | |'''P12'''||'''<nowiki>[4321]</nowiki><ref name="ftn6">'''<nowiki>In brackets [ ] default values are shown.</nowiki>'''</ref> = Access code (PIN) – '''is used to opening door electro-lock. |
− | + | Value change: | |
− | <nowiki><Enter> |----| | + | <nowiki><Enter> |----| entering new PIN</nowiki> |
− | + | This number is one for all system and its change on one cassette changes number in whole system. It should cosists of 4 digits. Setting value '''''0000''' ''<nowiki>lock possibility of entering usung access code [opening electro-lock can occurs only from PABX (by PABX subscriber) or using proximity identifiers reader].</nowiki> | |
|- | |- | ||
|'''P13'''|| '''<nowiki>[5] = Czas otwarcia elektrozamka w sekundach.</nowiki>''' | |'''P13'''|| '''<nowiki>[5] = Czas otwarcia elektrozamka w sekundach.</nowiki>''' |
Revision as of 08:04, 7 March 2011
Contents
- 1 SKD
- 2 Features of Slican doorphones
- 3 Installation
- 4 Korzystanie z systemu kontroli dostępu
- 5 Wymogi bezpieczeństwa w użytkowaniu bramofonów serii SKD
- 6 Deklaracja zgodności, prawidłowe usuwanie produktu
- 7 Notatki
SKD
KD12N KD12P KN12N KN12P
Features of Slican doorphones
SKD series doorphones are equiped in numeric keyboard and display. There are manufactured as following models:
Code | Description |
---|---|
SKD.RF-KN12P | Underplaster, without apartment list |
SKD.RF-KN12N | Overplaster, without apartment list |
SKD.RF-KD12P-graph | Underplaster, with apartment list |
SKD.RF-KD12N-graph.al | Overplaster, with apartment list and protection frame |
SKD doorphones can work with following Slican PBXes[1]:
- Slican CMT,
- Slican PMS-08,
- Slican CCA-2720,
- Slican NCT-1248,
- Slican CCT-1668,
- Slican MAC-6400.
Following table presents number of doorphones possible to connect, depending on PBX type (Table 1).
PBX type | Maximal number of doorphones |
---|---|
Slican CMT | 2 |
Slican PMS-08 | 2 |
Slican CCA-2720 | Half of maximal number of internal analogue lines |
Slican NCT-1248 | Half of maximal number of internal analogue lines |
Slican CCT-1668 | 20 |
Slican MAC-6400 | 20 |
Slican ITS-02XX; ITS-01XX | 6 |
Doorphone connection method is the same for all PBX types, differences are visible only while PBX programming (to know how to programm PBX to working with doorphone, see PBX programming instruction).
SKD doorphones are devices, which enable following activities:
- dialing PBX extension number to establish call, using touch keypad (phone like),
- extablish call after dialing doorphone number (listening),
- switching electro-lock (opening door) directly from phone while conversation, using PIN codes or using proximity identifiers (card or pendant),
- possibility of connecting additional button or movement detector for opening door,
- possibility of connecting opening door button,
- audio status signaling – pressing button, disconnection, etc.,
- call time duration – not longer than 3 minutes,
- power supply by save voltage 12VAC or 12VDC,
- proximity identifiers reader included in doorphone + possibility of connecting one additional (external) proximity reader Slican SKD.CKZ-10,
- maintenance up to 500 proximity identifiers (users),
- 2 working modes: local and global.
Cassete dimensions
Dimensions of doorphone cassete SKD.RF.KD12N and SKD.RF.KD12P
Installation
Doorphones are available in several versions – see Table 2. They are connected to the PABX using two wires. Additionally button or movement detector can be connected to doorphone, they enable to opening door from inside.
Symbol | Mounting method |
---|---|
SKD.RF-KN12P | underplaster |
SKD.RF-KN12N | overplaster |
SKD.RF-KD12N | overplaster |
SKD.RF-KD12P | underplaster |
Doorphones require appropriate transformer[2] or DC power supply[3], which is needed for supplying doorphone and electrolock. Electrolock should be acquired separately, depemding on needs – control voltage 12VAC or 12VDC (while doorphone supply with DC).
Opening doorphone casing
Fig. 2: Elements of SKD series doorphone
Symbol | Element |
---|---|
1 | Top panel fixing bolt |
2 | Loudspeaker cover |
3 | Display and proximity identifiers reader |
4 | touch keypad |
5 | Microphone cover |
6 | Mounting holes |
7 | Hole for providing cables |
Casing can be open by unscrew bolt located in front panel (see pos. 1 on Fig. 3). After unscrewing bolt following operations are possible:
- Front panel disassembly – Lift front panel about 30° from vertical and draw it up from the hinges – see pos. 2 on Fig. 3.
- Front panel lifting by 90° (perpendicular to the rest of casing) – this position is helpful during connecting wires to terminal (front panel is locked)– see pos. 3 on Fig. 3.
Fig. 3: Opening and inclination of front panel of KN casing
Fig. 4 Opening and inclination of front panel of KD12 casing
Doorphone installation
As standard, doorphone can be used for over- and under-plaster mounting. To mount doorphone, front panel should be removed (see chapter 2.1).
Over-plaster installation
Doorphone can be mounted on the outside of wall or column (Fig. 5). Housing for over-plaster mounting should be fixed by three stretcher pins fi 8. Wires should be entered by hole in the back side.
Fig. 5. Over-plaster SKD doorphone mounting
Under-plaster installation
Appropriate hole should be forge and brick up evenly to the wall face, as it is seen on Fig. 5. Wires should be conducted on the back side, under the plaster.
Rys. nr 5: Montaż podtynkowy bramofonu SKD
Doorphone connection
Doorphone power supply circuit should include easy to access disconnecting device, which is part of building installation, due to this device it is possible to perform service activities while power supply is on.
If power supply source is included in PBX, which dooz którą bramofon ma współpracować, to do bramofonu należy doprowadzić co najmniej3-parowy kabel[4]:
- 2 wires (1 para) – connection with PBX analogue port, which works as doorphone port,
- 2 wires (1 para) – power supply,
- 1 wire – earthing.
Supply cable should not be longer then 20m and cross-section 0,5mm2 (standard phone cable), while for longer distances wire should be thicker. Voltage drop on wires while electro-lock is on (depends on type of used electro-lock) can causes improper device operation.
Fig. 6: Connection of SKD doorphone
Description of terminals
Terminal description | Terminal destination | |||
---|---|---|---|---|
12V AC | Terminals for connecting external doorphone power supply source – voltage12VAC. To these terminals secondary winding of the transformer included in doorphone set. | |||
+12V / GND | Terminals for connecting external doorphone power supply source – voltage12VDC. Polarity of connection wires should be observed. Device is protected against improper polarity connection, but doesn't operate. | |||
| ||||
C / NO[5] (NC) | Terminals for relay output used to controll electro-lock. They should be connected in series in electro-lock supply circuit. Due to using NO terminal (terminals stay closed for a programmed time) or NC (terminals stay open for a programmed time) it is possible to connect any device controlling opening door. | |||
POD /GND | To these terminals button or movement sensor can be connected, which are used to opening door from inside. Closing these terminals (pressing button) causes relay switching on, for a time of pressing button plus time defined during doorphone programming, this time starts running after releasing button. Such button (movement sensor) operate independently on doorphone status (call, standby mode). | |||
COD / GND | These terminals can be used for connecting opening door sensor (reed relay). COD terminal is used to immediate switchng off electro-lock while door is open. | |||
TIP / RING | These terminals can be used for connecting one of PABX analogue port, which is used as doorphone port. Wires polarity has no meaning. | |||
A(D+)/B(D-) | Terminals to connect wires for data transmission between doorphones acordingh RS-485 standard. | |||
UZ | Earting terminal – for earthing doorphone. Earting wire can be also connected to the bolt assigned as . | |||
+5V / GND | Terminals for connecting power supply to additional proximity card reader. | |||
DIN, DOUT, CLK | Terminals for data transmission between doorphone and additional proximity card reader. | |||
LEDG, LEDR, BUZ | Terminals for connecting remain wires required for additional proximity card reader operation. |
Remain configurational elements:
Configuration of PBX for doorphone cooperation
To assure proper operation of SKD doorphone, PBX should be apropriatelly configured, analogue port with doorphone connected should be defined as doorphone.
PABX programming method depends on PBX type – see manual attached to the PBX.
Installation of proximity card reader SKD.CKZ-10
SKD doorphone includes proximity idetifiers reader, althiugh it is possible to connect additional reader SKD.CKZ-10. It is mounted to the wall using two fixing bolts 5 and appropriate screws (attached to the set). Mounting surface should be flat. Reader is resistant for moisture, so it can be mounted otside the building.
Reader is connected to the doorphone via 8-wires cable, this cable is integral part of reader. All wires are assigned by colours and these colours should be observed while connecting.
|
No. | Reader wire colour | Doorphone terminal description |
---|---|---|
1 | Red | +5V |
2 | Blue | GND |
3 | Brown | BUZ |
4 | Green | LEDG |
5 | White | DOUT |
6 | Purple | DIN |
7 | Yellow | LEDR |
8 | Grey | CLK |
Table 3: Connecting reader SKD.CKZ-10 cable to doorphone terminals
Connecting cable is 5 meters long and due to assuring working parameters this cable can't be extend. So distance between doorphone and reader location should be observed. Range of proximity identifiers reader is up to 10cm and depends on type of used proximity identifier (card, pendant).
Doorphone programming
Doorphone working modes
Doorphone can operate in local or global mode. In local mode doorphone is not connected to any other doorphone (RS-485 bus terminals RS-485 bus terminals are not used) in opposite in global mode all doorphones are connected between themselves. Due to such connection parameters changes made on one doorphone are visible in remain doorphones, but only some settings are copy:
- Access code (code for opening door) – option P12,
- list of proximity identifiers - option P31.
Used in RS-485 differential transmission protect data against external disturbances (ex. inductive devices – motors), it is recommended to use shielded twisted pair cat.5 (STP cat.5[3]) to assure additional protection. Maximal distance between extreme doorphones cannot be longer than 1200 meters (in extreme doorphones it is recommended to instal JP2 jumper, it is equal to use terminators).
If in global mode on any doorphone in standby status dot on display flashes, it means that connection between this doorphone and MASTER cassette (in this cassette the most current database version is stored) was broken for one of following reasons:
- damage of RS-485 databus wire
- no MASTER cassette power supply
In such situation programming procedure mustn't be executed from doorphone with no connection until failure will be fixed. After fixing this failure standby status dot stop flashing.
Entering programming mode
To enter programming mode:
- Press 3 time button – on display|----| flashes.
- Select standard access code to the programming menu: 1234 (this access code is set as default – there is possibility of change this code). Time to entering this code is limited to 10 seconds, starting from first pressing key. Return to the standby mode (| .| on display) takes place after this time (if access code isn't entered) or immedietelly (after entering wrong value of access code).
- |P--| is shown on display, it means that you entered programming mode[4].
|
Programming options
|
Programming is base on sellection and setting value of specified doorphone options (P11 to P41). Detailed description of these options is presented in Table 4.
In programming process following keys are used:
1 | 2 ↑ | 3 |
← 4 | 5 | 6 → |
7 | ↓ 8 | 9 |
0 | C |
- 2 (up) and 8 (down) – option selection,
- 6 – entering selected option,
- (Enter) – entering parameter edition/accepting entered value or selected option,
- C (Cancel) – return to enter position without any changes.
|
Example:
To change programming access code, following steps should be done:
- In entering mode select option P41 [after displaying text |P--| on doorphone display, use keys ↑↓ or selecting key (text |P--| starts flashing), next pressing 41 and accept with key].
- Select option with → key (digit 6) – current value, access code to programm menu is displayed (as default 1234).
- Press key - text |----| starts flashing.
- Enter new access code and accept it by pressing .
- New value is displayed, it confirms entering this value.
- Exit this option by pressing C key (after single pressing causes exit changed option – display |P41|, double pressing - display |P--|).
Option | Description |
---|---|
General settings | |
P11 | Cassette phisical number (ID).
This field has information meaning and depends on jumper location on CONFIG terminal (allowed value are from 0..15). Every cassette number must be unique if there are few doorphones in the system. |
P12 | [4321][6] = Access code (PIN) – is used to opening door electro-lock.
Value change: <Enter> |----| entering new PIN This number is one for all system and its change on one cassette changes number in whole system. It should cosists of 4 digits. Setting value 0000 lock possibility of entering usung access code [opening electro-lock can occurs only from PABX (by PABX subscriber) or using proximity identifiers reader]. |
P13 | [5] = Czas otwarcia elektrozamka w sekundach.
Zmiana wartości: <Enter> |--| wprowadź nowy czas Jest to czas, przez jaki będzie otwarty rygiel po zwolnieniu klawisza * przez abonenta centrali, po wprowadzeniu numeru PIN lub odczytaniu karty zbliżeniowej (breloka). Zakres regulacji = 1..30 |
P14 | [no][7] = Gorąca linia po wybraniu cyfry "0".
Zmiana wartości: <Enter> <up> lub <down> - wciskanie klawisza w górę lub w dół powoduje zmianę na wartość przeciwną (no --> YES lub YES --> no) Wciśnięcie przycisku 0 spowoduje tylko zamknięcie pętli – trzeba wtedy skierować ruch w centrali poprzez „gorącą linię”. |
Przekierowania [8] | |
P21 | [1] = Numer katalogowy przycisku 1.
Po naciśnięciu danego przycisku bramofon wybiera cyfry w systemie DTMF, zależne od tego ustawienia. |
P22 | [2] = Numer katalogowy przycisku 2. |
P23 | [3] = Numer katalogowy przycisku 3. |
P24 | [4] = Numer katalogowy przycisku 4. |
P25 | [5] = Numer katalogowy przycisku 5. |
P26 | [6] = Numer katalogowy przycisku 6. |
P27 | [7] = Numer katalogowy przycisku 7. |
P28 | [8] = Numer katalogowy przycisku 8. |
P29 | [9] = Numer katalogowy przycisku 9. |
P31 | Dodawanie identyfikatorów zbliżeniowych do systemu.
Maksymalna liczba identyfikatorów wynosi 500.
|
P32 | Usuwanie wszystkich identyfikatorów zbliżeniowych
|
Bezpieczeństwo | |
P41 | [1234] = Kod dostępu do menu programowania.
Zmiana wartości: <Enter> |----| wprowadź nowy kod Kod ten jest wymagany, aby wejść w tryb programowania danego bramofonu. Musi się składać z 4 cyfr. |
Korzystanie z systemu kontroli dostępu
Korzystanie z bramofonu
Połączenie Bramofon → Abonent
Naciśnięcie dowolnego przycisku bramofonu jest sygnalizowane pojedynczym, krótkim dźwiękiem, a w przypadku wybierania cyfr są one dodatkowo prezentowane na wyświetlaczu. Z klawiatury bramofonu można wybrać numer katalogowy abonenta (lub grupy abonentów) albo jedną z cyfr z zakresu 0..9 [11], co przy prawidłowej konfiguracji bramofonu i centrali spowoduje, że u wybranego abonenta (bądź grupy abonentów) zadzwoni telefon. W czasie wywoływania na wyświetlaczu jest widoczny wybrany numer [12], a w głośniku słyszany jest sygnał (zależny od centrali, do której bramofon jest podłączony). Po podniesieniu słuchawki przez abonenta następuje rozmowa. Jeśli abonent po rozmowie odłoży słuchawkę,do bramofonu zostanie wysłany rozkaz powodujący jego rozłączenie się -w jego głośniku pojawi się pojedynczy sygnał akustyczny, a wyświetlacz wróci do stanu spoczynkowego (| .|). Czas trwania rozmowy jest ograniczony do 3 minut - po tym czasie bramofon rozłącza się, sygnalizując to trzema krótkimi dźwiękami i powrotem wyświetlacza do stanu spoczynkowego. U abonenta pojawi się sygnał zajętości lub nieosiągalności.
Gdy po wybraniu numeru abonent nie zgłosi się przez określony czas (zależny od centrali, z którą bramofon współpracuje), centrala zakończy wywoływanie. Także wciśnięcie przycisku w czasie wywoływania spowoduje jego zakończenie (w przypadku rozmowy nastąpi jej rozłączenie) i powrót do stanu spoczynkowego.
Połączenie Abonent → Bramofon
Jeżeli abonent centrali wybierze z telefonu numer bramofonu, zostanie zestawiona rozmowa z bramofonem. W czasie takiej rozmowy (podsłuchu) na wyświetlaczu jest napis „CALL”. Jeśli abonent po rozmowie odłoży słuchawkę, do bramofonu zostanie wysłany rozkaz powodujący jego rozłączenie się - w jego głośniku pojawi się pojedynczy sygnał akustyczny,a wyświetlacz wróci do stanu spoczynkowego (| .|). Czas trwania rozmowy jest ograniczony do 3 minut - po tym czasie bramofon rozłącza się, sygnalizując to trzema krótkimi dźwiękami i powrotem wyświetlacza do stanu spoczynkowego. U abonenta pojawi się sygnał zajętości lub nieosiągalności (ten sam sygnał pojawi się, jeśli połączenie zostanie zakończone od strony bramofonu - poprzez naciśnięcie klawisza C).
Otwieranie drzwi (bramy)
Abonent może otworzyć rygiel elektrozamka w trakcie trwania rozmowy, wybierając z telefonu z wybieraniem DTMF znak „*” (w czasie gdy abonent naciska na ten klawisz słychać ton mu odpowiadający w głośniku bramofonu), po zwolnieniu przycisku powraca do dalszej rozmowy, a rygiel elektrozamka pozostaje jeszcze otwarty przez zaprogramowany czas. Można np. zaprogramować w pamięci telefonu numer: [„nr bramofonu” pauza *], który będzie powodował otwarcie bramy bez konieczności zestawiania rozmowy.
Dodatkowo istnieje możliwość zastosowania przycisku otwarcia drzwi (POD) lub czujki ruchu. W tym przypadku otwarcie jest sygnalizowane krótkim sygnałem dźwiękowym.
System kontroli dostępu pozwala także otwierać drzwi za pomocą zdefiniowanego kodu dostępu (patrz [#Opcja P12 w trybie programowania opcja P12 w trybie programowania]). Procedura jest następująca:
- W stanie spoczynku nacisnąć klawisz („kluczyk”).
- Na wyświetlaczu pojawi się ----.
- Wprowadzić zaprogramowany kod dostępu – na wyświetlaczu pojawią się symbole zamiast cyfr, aby uniemożliwić ewentualne podejrzenie PIN-u.
- Jeśli kod jest poprawny, na wyświetlaczu zostanie wyświetlony napis OPEn, sygnalizując otwarcie rygla. W przeciwnym przypadku bramofon wróci do stanu spoczynkowego - |----|.
Korzystanie z czytników identyfikatorów zbliżeniowych
Otwarcie rygla elektrozamka przy pomocy wcześniej zapamiętanego identyfikatora zbliżeniowego w postaci karty lub breloka możliwe jest w następujących stanach bramofonu:
- każdy stan (spoczynkowy, rozmowy lub wołania) – z dodatkowego czytnika SKD.CKZ-10,
- tylko w stanie spoczynkowym – z wbudowanego czytnika.
W tym celu należy zbliżyć kartę (brelok) do wyświetlacza (dookoła niego znajduje się antena wbudowanego czytnika) lub do zewnętrznego czytnika. Następuje wtedy weryfikacja unikalnego kodu zapisanego w identyfikatorze zbliżeniowym i jeśli jest on zgodny z zapisanym w pamięci, to następuje zwolnienie rygla elektrozamka (otwarcie drzwi), co jest sygnalizowane pojedynczym sygnałem dźwiękowym oraz pojawieniem się napisu OPEn na wyświetlaczu bramofonu. W sytuacji jeżeli weryfikacja zakończy się niepowodzeniem (brak identyfikatora w bazie danych), to bramofon sygnalizuje ten fakt dwoma krótkimi sygnałami akustycznymi i nie otwiera elektrozamka. Jeśli odczyt następuje przy użyciu SKD.CKZ-10, to wyżej opisane stany są także prezentowane za pomocą diody dwukolorowej oraz sygnałów dźwiękowych tego czytnika, co prezentuje poniższa tabela.
Dioda Zielona | Dioda Czerwona | Brzęczyk ( Buzzer) | Stan pracy systemu |
---|---|---|---|
zgaszona | świeci | nieaktywny | drzwi zamknięte |
świeci | zgaszona | nieaktywny | drzwi otwarte |
świeci | zgaszona | 1 x długi dźwięk(0,8 sekundy) | otwarcie drzwi przy użyciu autoryzowanej karty, kodu dostępu lub przycisku otwarcia od wewnątrz |
zgaszona | podwójne mignięcie | 2 x krótki dźwięk(0,2 s każdy) | karta niezarejestrowana w systemie – odmowa dostępu |
Wymogi bezpieczeństwa w użytkowaniu bramofonów serii SKD
Dokładne przestrzeganie zasad bezpieczeństwa i prawidłowego użytkowania jest bezwzględnie wymagane dla zapewnienia prawidłowego działania urządzenia.
Poniżej przedstawione zasady są podstawą przy uwzględnianiu wszelkich reklamacji i uwag ze strony użytkowników przez producenta.
Przedstawione tu zasady dotyczą instalacji, umiejscowienia i wymagań,co do sieci elektrycznej i teleinformatycznej.
Instalacja
- Urządzenie powinno być zainstalowane i uruchomione przez autoryzowany serwis posiadający uprawnienia producenta.
- Wszystkie czynności instalacyjne powinny być wykonywane z zachowaniem zasad montażu i przepisów BHP.
Środowisko pracy
- Ze względu na trwałość i jakość pracy podzespołów elektronicznych urządzenie nie powinno być montowane w pomieszczeniach, w których utrzymuje się duża wilgotność powietrza. Obudowa bramofonu jest odporna na czynniki atmosferyczne, jednak w przypadku montażu na zewnątrz budynku zalecana jest instalacja w osłoniętym miejscu, tak aby uniknąć, np. strug deszczu bezpośrednio padających na urządzenie czy wiatru, który może utrudniać rozmowę przez bramofon.
- Ze względu na ryzyko zalania wodą nie powinno być umieszczane w pobliżu zbiorników z wodą lub źródeł jej strumieni (np. baseny, krany).
- Bramofon nie może być umieszczany w pomieszczeniach o silnym zapyleniu ani w pomieszczeniach o dużym natężeniu pola elektromagnetycznego.
Ze względu na możliwość nieprawidłowego funkcjonowania, zakłócenia lub odbarwienie obudowy nie zaleca się instalowania systemu w następujących miejscach:
- w miejscach o bezpośrednim działaniu promieni słonecznych;
- w miejscach, gdzie wibracje lub uderzenia są szczególnie częste lub silne;
- w pobliżu anten radiowych.
Inne wymagania
- Urządzenie powinno mieć prawidłowe uziemienie.
- Źródło zasilania bramofonu musi posiadać zabezpieczenie przeciwzwarciowe o wartości 2A.
- Wszystkie urządzenia dołączane do bramofonu powinny mieć świadectwa zgodności z normami obowiązującymi w Unii Europejskiej.
Deklaracja zgodności, prawidłowe usuwanie produktu
Notatki
- ↑ PBX must be equiped with DTMF module (CCA, PMS, NCT, CCT i MAC - standard, CMT - option).
- ↑ Transformer 230V/12Vac, min 10VA with overcurrent protection of 2A. In our offer there are different transformers, which fulfils these conditions.
- ↑ 3.0 3.1 Power supply 230Vac/12Vdc, min 10W with overcurrent protection of 2A
- ↑ 4.0 4.1 If doorphone installation is located inside the building gelating cable should be used.
- ↑ NO (Normally Open), NC (Normally Closed); maximal load capacity of NO and NC is equal to 24V, 2A
- ↑ In brackets [ ] default values are shown.
- ↑ no (ang.) - nie, yes (ang.) - tak
- ↑ Wykorzystywane, jeżeli bramofon jest podłączony do centrali.
- ↑ add (ang.) - dodaj
- ↑ dEL (od ang. delete) - usuń„
- ↑ Jeżeli analogowa linia wewnętrzna z centrali do bramofonu jest uszkodzona lub niepodłączona,to wybór dowolnego numeru spowoduje wygenerowanie trzech krótkich dźwięków.
- ↑ Jeśli wybraliśmy błędny numer, można powrócić do stanu spoczynkowego bramofonu, naciskając klawisz C.