(Created page with "Connecting doorphone can be executed via appropriate cables connected to connecting terminal located on doorphone PCB. Connecting terminal is visible and accessible afer unscr...") |
|||
Line 7: | Line 7: | ||
|[[File:Ikona uziemiena biała.PNG]] || earthing (for proper operation of doorphone over-voltage protection) | |[[File:Ikona uziemiena biała.PNG]] || earthing (for proper operation of doorphone over-voltage protection) | ||
|- | |- | ||
− | |LAN || RJ45 socket for LAN cable | + | |LAN || RJ45 socket for LAN cable (PoE support) |
|- | |- | ||
|EZ ||rowspan="2"| electrolock, 12V DC, max 0.7A | |EZ ||rowspan="2"| electrolock, 12V DC, max 0.7A | ||
Line 30: | Line 30: | ||
Connection scheme of doorphone DPH is presented on following figure.<br> | Connection scheme of doorphone DPH is presented on following figure.<br> | ||
<center>[[File:Schemat podlaczenia DPH.png]]</center><br> | <center>[[File:Schemat podlaczenia DPH.png]]</center><br> | ||
− | DPH doorphone supply can be realized using AC | + | DPH doorphone supply can be realized using AC, DC or PoE. Power supply device should be selected according user needs. Due to wide possibilities, Slican company doesn't offerany power supply device together with DPH doorphone, it remain to user decision. In Slican offer - as a separate position in price list - there is AC transformer TRS10-V18-N, with nominal voltage equal to 18V, this transformer fulfil supply requirements of DPH doorphone. Below is presented mentioned above transformer: |
<center> [[File:Trafo TRS10-V18-N.png|250px]]</center> | <center> [[File:Trafo TRS10-V18-N.png|250px]]</center> |
Revision as of 09:00, 27 March 2017
Connecting doorphone can be executed via appropriate cables connected to connecting terminal located on doorphone PCB. Connecting terminal is visible and accessible afer unscrewing front panel, this operation is described in chapter DPH - Opening doorphone casing.
|
Connections located in connection terminal, usetd to doorphone installation are presented in following table:
Connection scheme of doorphone DPH is presented on following figure.
DPH doorphone supply can be realized using AC, DC or PoE. Power supply device should be selected according user needs. Due to wide possibilities, Slican company doesn't offerany power supply device together with DPH doorphone, it remain to user decision. In Slican offer - as a separate position in price list - there is AC transformer TRS10-V18-N, with nominal voltage equal to 18V, this transformer fulfil supply requirements of DPH doorphone. Below is presented mentioned above transformer: