Difference between revisions of "Technical data CXS WM"
From pubWiki-en
(Created page with "== Technical data == * power supply 230VAC, 50Hz, * power consumption max. 120 VA (for all PABX ports occupation), * protection against overcurrents and overvoltage from telecom...") |
(→Technical data) |
||
(4 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
== Technical data == | == Technical data == | ||
* power supply 230VAC, 50Hz, | * power supply 230VAC, 50Hz, | ||
− | * power consumption max. | + | * power consumption max. 45 VA (for all PBX ports occupation), |
* protection against overcurrents and overvoltage from telecommunication network, | * protection against overcurrents and overvoltage from telecommunication network, | ||
* analogue internal ports with pulse and tone (DTMF) dialing, | * analogue internal ports with pulse and tone (DTMF) dialing, | ||
Line 10: | Line 10: | ||
* configurable ISDN BRA 2B+D ports (terminals ISDN S/T), | * configurable ISDN BRA 2B+D ports (terminals ISDN S/T), | ||
* ports of analogue trunks, | * ports of analogue trunks, | ||
− | * terminals:<br/> - ISDN 2B+D – DSS1 protocol (EURO – ISDN),<br/> - | + | * terminals:<br/> - ISDN 2B+D – DSS1 protocol (EURO – ISDN),<br/> - analogue external trunks, according ASS signaling, <br/> - GSM – Dual Band: GSM 900, GSM 1800,<br/> - VoIP – via LAN, WAN interfaces- according SIP, IAX protocols, (codecs: GSM, G.711a/μ, G.729), <br/> - U<sub>p0</sub> – digital terminals for system phones CTS-202.CL, CTS-202.BT. |
− | * | + | * ports for CTS series system phones (Up0 terminal), |
− | * | + | * support of CTS-202.IP and CTS-102.IP system phones, |
− | * | + | * support of ISDN digital phones with DSS1 signalling, |
− | * | + | * Ethernet 10/100 ports with support of CTI system clients and VoIP calls, |
− | + | * GSM modules, | |
− | * | + | * fulfils the requirements of the R&TTE directive. |
** LVD, | ** LVD, | ||
** EMC, | ** EMC, | ||
** R&TTE. | ** R&TTE. |
Latest revision as of 11:13, 14 January 2011
Technical data
- power supply 230VAC, 50Hz,
- power consumption max. 45 VA (for all PBX ports occupation),
- protection against overcurrents and overvoltage from telecommunication network,
- analogue internal ports with pulse and tone (DTMF) dialing,
- ISDN phones with DSS1 signaling operation,
- full functionality for phones with DTMF,
- CLIP signaling: internal and transfered to external lines,
- CLIP receiving in FSK system on analogue trunks,
- configurable ISDN BRA 2B+D ports (terminals ISDN S/T),
- ports of analogue trunks,
- terminals:
- ISDN 2B+D – DSS1 protocol (EURO – ISDN),
- analogue external trunks, according ASS signaling,
- GSM – Dual Band: GSM 900, GSM 1800,
- VoIP – via LAN, WAN interfaces- according SIP, IAX protocols, (codecs: GSM, G.711a/μ, G.729),
- Up0 – digital terminals for system phones CTS-202.CL, CTS-202.BT. - ports for CTS series system phones (Up0 terminal),
- support of CTS-202.IP and CTS-102.IP system phones,
- support of ISDN digital phones with DSS1 signalling,
- Ethernet 10/100 ports with support of CTI system clients and VoIP calls,
- GSM modules,
- fulfils the requirements of the R&TTE directive.
- LVD,
- EMC,
- R&TTE.