Difference between revisions of "MSB-1102 Instruction manual"
From pubWiki-en
(→MSB-1102 Structure) |
(→Certificate of conformity, proper equipement disposal) |
||
(8 intermediate revisions by the same user not shown) | |||
Line 13: | Line 13: | ||
MSB-1102 is equipped with following input/output ports: | MSB-1102 is equipped with following input/output ports: | ||
*sockets AB1/AB2 type RJ11 for connecting 2 subscriber ports in PABX, | *sockets AB1/AB2 type RJ11 for connecting 2 subscriber ports in PABX, | ||
− | *socket 2REL<ref name="funkcje"> | + | *socket 2REL<ref name="funkcje">Device uses 2 independent channels. It means that simultaneously two functions can operate. Ex: 2 sensors, 2 relays or mix.</ref> (REL1/REL2) type RJ45 which includes: |
**sensor terminals (SNS1/SNS2) – configurable, | **sensor terminals (SNS1/SNS2) – configurable, | ||
**monostable relay terminals<ref name="czas_impulsu>Release pulse time is about 1 second.</ref> – configurable, | **monostable relay terminals<ref name="czas_impulsu>Release pulse time is about 1 second.</ref> – configurable, | ||
Line 21: | Line 21: | ||
==Configuration Jumpers== | ==Configuration Jumpers== | ||
{| | {| | ||
− | |[[ | + | |[[File:MSB jumpers small.png]]|| |
{|{{prettytable}} | {|{{prettytable}} | ||
− | |X1-X3 - | + | |X1-X3 - Sensor 1 operating mode (SNS1)||X4-X6 - Sensor 2 operating mode (SNS2) |
|- | |- | ||
− | |X10-X12 – | + | |X10-X12 – Relay 1 operating mode (REL1)||X7-X9 - Relay 2 operating mode (REL2) |
|- | |- | ||
|} | |} | ||
Line 33: | Line 33: | ||
=Operating modes= | =Operating modes= | ||
{|{{prettytable}} | {|{{prettytable}} | ||
− | !{{Hl3}}| | + | !{{Hl3}}|Power supply!! {{Hl3}}|Sensors (SNS)!!{{Hl3}}|Relays (REL) |
|- | |- | ||
− | | | + | |Without power supply||[[File:MSB DCI mode.png]]<br>||[[File:MSB REL NO NC small.png]] |
|- | |- | ||
− | | | + | |With power supply||[[File:MSB CCS mode.png]]||[[File:MSB VON VOFF small.png]] |
|- | |- | ||
|} | |} | ||
− | + | According above table '''MSB-1102''' must be supplied from local power supply device in following operating modes: | |
− | * | + | * Sensors: CCS mode |
− | * | + | * Relays: VON/VOFF mode |
=Parameters= | =Parameters= | ||
− | * | + | * current downloaded from power supply unit in CCS mode - max. 20mA. |
− | * | + | * current downloaded in DCI mode - max.10mA per sensor. |
− | * | + | * relay terminal parameters (for NO/NC and VON/VOFF modes) - max 42VAC/0.5A, 42VDC/1A |
− | * | + | * Sensor activate voltage range - DCI and CCS modes - 5-30V<ref name="polaryzacja">Attention: Polarity is important</ref>DC. |
<br> | <br> | ||
− | {{warning| | + | {{warning|It is not allowed to direct controlling with 230VAC voltage. For this purpose, appropriate external relays, connected to 2REL socket should be used.}} |
− | =[[MSB | + | =[[MSB Certificate of conformity |Certificate of conformity, proper equipement disposal]]= |
---- | ---- | ||
{{References}} | {{References}} |
Latest revision as of 10:53, 10 January 2011
Contents
Information
Slican Multi Switch Box MSB-1102 it is device assuring cooperation between Slican PABX[1] and sensors, relays, alarm systems, paging systems etc.
Subscriber port in PABX should be configured as Sensor or Relay – depending on required function.
MSB-1102 Structure
MSB-1102 is equipped with following input/output ports:
- sockets AB1/AB2 type RJ11 for connecting 2 subscriber ports in PABX,
- socket 2REL[2] (REL1/REL2) type RJ45 which includes:
- sensor terminals (SNS1/SNS2) – configurable,
- monostable relay terminals[3] – configurable,
- socket ZAS – local power supply from external source.
Connecting and preparing for configuration
Configuration Jumpers
|
Operating modes
Power supply | Sensors (SNS) | Relays (REL) |
---|---|---|
Without power supply | ||
With power supply |
According above table MSB-1102 must be supplied from local power supply device in following operating modes:
- Sensors: CCS mode
- Relays: VON/VOFF mode
Parameters
- current downloaded from power supply unit in CCS mode - max. 20mA.
- current downloaded in DCI mode - max.10mA per sensor.
- relay terminal parameters (for NO/NC and VON/VOFF modes) - max 42VAC/0.5A, 42VDC/1A
- Sensor activate voltage range - DCI and CCS modes - 5-30V[4]DC.
|
Certificate of conformity, proper equipement disposal
References
- ↑ MSB-1102 can be used with firmware version 4.10 or later. It can be used with Slican PABXes: CXS-0424, CCT-1668, MAC-Zero, MAC-6400.
- ↑ Device uses 2 independent channels. It means that simultaneously two functions can operate. Ex: 2 sensors, 2 relays or mix.
- ↑ Release pulse time is about 1 second.
- ↑ Attention: Polarity is important