Difference between revisions of "Characteristic of Slican DPH doorphones"

From pubWiki-en
Jump to: navigation, search
 
(2 intermediate revisions by the same user not shown)
Line 1: Line 1:
Slican DPH doorphones connected to PBX enable to establish call between person near doorphone and PBX subscriber, as well as enter to protected area. It is also possible to trigger an electrolock, for opening door or gate, from phone connected to PBX. Following functions are available in DPH doorphones:
+
{{Warning|
* establish phone call using touch button
+
Slican doorphones DPH.AB with DG note mean new colour version – Dark Graphite. Funcionally they do not differ from version without DG}}
* two relays trigger
+
 
 +
 
 +
Slican DPH.AB doorphones connected to PBX via an existing telephone network allows people who intend to enter closed area to communicate with persons in that area. Also it allows enter to protected area by activating electrolock which control opening of door or gate:
 +
 
 +
* using telephone being called by selecting appropriate DTMF code on acoustics - * (asterisk), digit 1 or 2
 +
* RFID version - proximity identifier
 +
* pressing POD button (door open button)
 +
 
 +
 
 +
DPH doorphones have following functional features:
 +
 
 +
* making a phone call using the capacitive button
 +
* controlling two outputs with:
 
** electrolock (EZ)
 
** electrolock (EZ)
 
** additional relay (STA)
 
** additional relay (STA)
* power supply with 12-25VAC or 14-35VDC
+
* power suppply: 18-25V AC lub 14-35V DC
* temperature range -20 to +70
+
* operating temperature range: -20 to +50<sup>o</sup>C
* protection level - according PN-EN 60529, IP34 for DPH and IP20 for power supply.
+
* security level - IP32
* inputs COD (opening door sensor) i POD (opening door button). Both buttons operate with electrolock.
+
* detection of PBX notification signal (INACCESS):
* EZ trigger (opening) by receiving "*" character in DTMF code
+
** frequency: 425Hz (+- 25Hz)
* embedded RFID card reader (not all models)
+
* Busy signal detection (BUSY):
* possibility to trigger EZ by registered RFID card approach
+
** frequency: 425Hz (+- 25Hz)
* STA trigger (second relay) by receiving "1" character in DTMF code. Single pulse with fixed duration time is generated
+
** signal/silence duration: 352ms - 608ms
* Doorphone parameters programming from phone using DTMF code
+
** number of consecutive signal and silence sequences detected: 3
 +
* detection of unreachable signal (CONGESTION):
 +
** frequency: 425Hz (+- 25Hz)
 +
** signal/silence duration: 192ms - 320ms
 +
** number of consecutive signal and silence sequences detected: 3
 +
* COD (door open sensor) and POD (door open button) inputs. Both inputs cooperate with electrolock
 +
* EZ or STA trigger (open) as result of receiving "*" in DTMF, depending on setting of corresponding parameter
 +
* EZ trigger as result of receiving "1" in DTMF
 +
* STA trigger (second output) as result of receiving "2" in DTMF. Single pulse of constant duration is generated
 +
* built-in RFID card reader (cards Unique 125kHz standard, compatible with EM4102 chip - doorphone version without RFID are also available)
 +
* option of EZ or STA triggering as result of approaching registered RFID card (in selected versions)
 +
* programming doorphone from phone using DTMF codes

Latest revision as of 11:05, 1 June 2020

Warning!

Slican doorphones DPH.AB with DG note mean new colour version – Dark Graphite. Funcionally they do not differ from version without DG


Slican DPH.AB doorphones connected to PBX via an existing telephone network allows people who intend to enter closed area to communicate with persons in that area. Also it allows enter to protected area by activating electrolock which control opening of door or gate:

  • using telephone being called by selecting appropriate DTMF code on acoustics - * (asterisk), digit 1 or 2
  • RFID version - proximity identifier
  • pressing POD button (door open button)


DPH doorphones have following functional features:

  • making a phone call using the capacitive button
  • controlling two outputs with:
    • electrolock (EZ)
    • additional relay (STA)
  • power suppply: 18-25V AC lub 14-35V DC
  • operating temperature range: -20 to +50oC
  • security level - IP32
  • detection of PBX notification signal (INACCESS):
    • frequency: 425Hz (+- 25Hz)
  • Busy signal detection (BUSY):
    • frequency: 425Hz (+- 25Hz)
    • signal/silence duration: 352ms - 608ms
    • number of consecutive signal and silence sequences detected: 3
  • detection of unreachable signal (CONGESTION):
    • frequency: 425Hz (+- 25Hz)
    • signal/silence duration: 192ms - 320ms
    • number of consecutive signal and silence sequences detected: 3
  • COD (door open sensor) and POD (door open button) inputs. Both inputs cooperate with electrolock
  • EZ or STA trigger (open) as result of receiving "*" in DTMF, depending on setting of corresponding parameter
  • EZ trigger as result of receiving "1" in DTMF
  • STA trigger (second output) as result of receiving "2" in DTMF. Single pulse of constant duration is generated
  • built-in RFID card reader (cards Unique 125kHz standard, compatible with EM4102 chip - doorphone version without RFID are also available)
  • option of EZ or STA triggering as result of approaching registered RFID card (in selected versions)
  • programming doorphone from phone using DTMF codes