!{{Hl1}}|<center><b>Call Manager</b></center> !!{{Hl1}}|<center><b>Description</b></center> !!{{Hl1}}|<center><b>Preview</b></center> | !{{Hl1}}|<center><b>Call Manager</b></center> !!{{Hl1}}|<center><b>Description</b></center> !!{{Hl1}}|<center><b>Preview</b></center> | ||
|- | |- | ||
− | | <center><b>NCP-CM300P<br>low traffic support</b></center> || <b>FUNCTIONAL FEATURES:</b> <br> | + | | <center><b>NCP-CM300P<br>NCP-CM300P.BC<br>low traffic support</b></center> || <b>FUNCTIONAL FEATURES:</b> <br> |
* Up to 40 simultaneous voice calls<br> | * Up to 40 simultaneous voice calls<br> | ||
* Up to 3 simultaneous video calls<br> | * Up to 3 simultaneous video calls<br> | ||
− | * Capacity: up to 5xNCP-GW, 58xTrunkGSM, 1xTrunkISDN-E1, 16xTrunkISDN-2B+D<br> | + | * Capacity: up to 5xNCP-GW, 50x TrunkSIP, 58xTrunkGSM, 1xTrunkISDN-E1, 16xTrunkISDN-2B+D<br> |
* Support for 64xCTS (Upn and IP)<br> | * Support for 64xCTS (Upn and IP)<br> | ||
− | * Up to 100 WebCTI/ | + | * Up to 100 WebCTI/MessengerCTI accounts<br> |
− | * Up to 300 subscriber equipment (FXS+SIP+CTS.Upn+CTS.IP)<br> | + | * Up to 300 subscriber equipment (FXS+SIP+CTS.Upn+CTS.IP+VN)<br> |
* Up to 40 simultaneous channels recorded<br> | * Up to 40 simultaneous channels recorded<br> | ||
− | * Storage space for | + | * Storage space for 3000h (WAV 64kb/s) or 13 000h (GSM 13kb/s)<br> |
* Billing buffer capacity of 500k events<br> | * Billing buffer capacity of 500k events<br> | ||
<b>HARDWARE FEATURES:</b><br> | <b>HARDWARE FEATURES:</b><br> | ||
− | * RACK SHELF 1.5U housing - depth | + | * RACK SHELF 1.5U housing - depth 360mm<br> |
− | * Mass storage device capacity: | + | * Mass storage device capacity: 120GB<br> |
* RJ45 interfaces: FE-LAN, FE-WAN/INT, 6xETH-INT<br> | * RJ45 interfaces: FE-LAN, FE-WAN/INT, 6xETH-INT<br> | ||
− | * 230VAC powering<br> | + | * 230VAC powering, buffer 12V DC in version NCP-CM300P.BC<br> |
|| [[Image:NCP-CM300P.png|300px]] | || [[Image:NCP-CM300P.png|300px]] | ||
|- | |- | ||
− | | <center><b>NCP-CM400P<br>average traffic support</b></center> || <b>FUNCTIONAL FEATURES:</b><br> | + | | <center><b>NCP-CM400P.BC<br>average traffic support</b></center> || <b>FUNCTIONAL FEATURES:</b><br> |
* Up to 100 simultaneous voice calls<br> | * Up to 100 simultaneous voice calls<br> | ||
* Up to 20 simultaneous video calls<br> | * Up to 20 simultaneous video calls<br> | ||
− | * Capacity: up to 20xNCP-GW, 120xTrunkGSM, 6xTrunkISDN-E1, 32xTrunkISDN-2B+D<br> | + | * Capacity: up to 20xNCP-GW, 200x TrunkSIP, 120xTrunkGSM, 6xTrunkISDN-E1, 32xTrunkISDN-2B+D<br> |
* Support for 400xCTS (Upn i IP)<br> | * Support for 400xCTS (Upn i IP)<br> | ||
− | * Up to 400 WebCTI/ | + | * Up to 400 WebCTI/MessengerCTI accounts<br> |
− | * Up to 1000 subscriber equipment (FXS+SIP+CTS.Upn+CTS.IP)<br> | + | * Up to 1000 subscriber equipment (FXS+SIP+CTS.Upn+CTS.IP+VN)<br> |
* Up to 100 simultaneous channels recorded<br> | * Up to 100 simultaneous channels recorded<br> | ||
− | * Storage space for | + | * Storage space for 3000h (WAV 64kb/s) or 13 000h (GSM 13kb/s)<br> |
* Billing buffer capacity of 500k events<br> | * Billing buffer capacity of 500k events<br> | ||
* [[NCP_redundancy|Redundancy]] feature<br> | * [[NCP_redundancy|Redundancy]] feature<br> | ||
<b>HARDWARE FEATURES:</b><br> | <b>HARDWARE FEATURES:</b><br> | ||
− | * RACK SHELF 1.5U housing - depth | + | * RACK SHELF 1.5U housing - depth 360mm<br> |
* Mass storage device capacity: 120GB<br> | * Mass storage device capacity: 120GB<br> | ||
* RJ45 interfaces: GbE-LAN, INT/RDU, GbE-WAN/INT, 8xETH-INT<br> | * RJ45 interfaces: GbE-LAN, INT/RDU, GbE-WAN/INT, 8xETH-INT<br> | ||
− | * 230VAC powering<br> | + | * 230VAC powering, buffer 12V DC<br> |
|| [[Image:NCP-CM400P.png|300px]] | || [[Image:NCP-CM400P.png|300px]] | ||
|- | |- | ||
− | | <center><b>NCP- | + | | <center><b>NCP-CM600P.BC<br>heavy traffic support</b></center> || <b>CECHY FUNKCJONALNE:</b><br> |
− | * Up to | + | * Up to 500 simultaneous voice calls |
− | * Up to | + | * Up to 40 simultaneous video calls |
− | * Capacity: up to 127xNCP-GW, 120xTrunkGSM, 13xTrunkISDN-E1, 32xTrunkISDN-2B+D | + | * Capacity: up to 127xNCP-GW, 300x TrunkSIP, 120xTrunkGSM, 13xTrunkISDN-E1, 32xTrunkISDN-2B+D |
* Support for 800xCTS(Upn i IP) | * Support for 800xCTS(Upn i IP) | ||
− | * Up to | + | * Up to 800 WebCTI/MessengerCTI accounts |
− | * Up to 10k subscriber equipment abonenckich (FXS+SIP+CTS.Upn+CTS.IP) | + | * Up to 10k subscriber equipment abonenckich (FXS+SIP+CTS.Upn+CTS.IP+VN) |
* Up to 300 simultaneous channels recorded | * Up to 300 simultaneous channels recorded | ||
− | * Storage space for | + | * Storage space for 6800h (WAV 64kb/s) or 30 000h (GSM 13kb/s)<br> |
* Billing buffer capacity of 500k events<br> | * Billing buffer capacity of 500k events<br> | ||
* [[NCP_redundancy|Redundancy]] feature<br> | * [[NCP_redundancy|Redundancy]] feature<br> | ||
<b>HARDWARE FEATURES:</b><br> | <b>HARDWARE FEATURES:</b><br> | ||
− | * RACK SHELF 1.5U housing - depth | + | * RACK SHELF 1.5U housing - depth 360mm<br> |
− | * Mass storage device capacity: | + | * Mass storage device capacity: 250GB<br> |
* RJ45 interfaces: GbE-LAN, INT/RDU, GbE-WAN/INT, 8xETH-INT<br> | * RJ45 interfaces: GbE-LAN, INT/RDU, GbE-WAN/INT, 8xETH-INT<br> | ||
− | * 230VAC powering<br> | + | * 230VAC powering, buffer 12V DC<br> |
|| [[Image:NCP-CM400P.png|300px]] | || [[Image:NCP-CM400P.png|300px]] | ||
|} | |} | ||
Line 68: | Line 68: | ||
!{{Hl1}} colspan="2"|<div align="left"><b>Terminals</b> | !{{Hl1}} colspan="2"|<div align="left"><b>Terminals</b> | ||
|- | |- | ||
− | | <center><b>CM300P | + | | <center><b>CM300P</b></center> || <center>8xFE(6xINT, 1xINT/WAN, 1xLAN)</center> |
|- | |- | ||
− | | <center><b>CM400P | + | | <center><b>CM400P</b></center> || <center>8xFE(6xINT, 1xLAN, 1xINT/WAN), 2xGbE(1xINT,1xINT/RDU)</center> |
|- | |- | ||
− | | <center><b>CM600P | + | | <center><b>CM600P</b></center> || <center>8xFE(6xINT, 1xLAN, 1xINT/WAN), 2xGbE(1xINT,1xINT/RDU)</center> |
|- | |- | ||
!{{Hl1}} colspan="2"|<div align="left"><b>Voice/Video</b> | !{{Hl1}} colspan="2"|<div align="left"><b>Voice/Video</b> | ||
|- | |- | ||
− | | <center><b>Voice and FAX codecs</b></center> || <center>G.711 A-law/U-law, G.722, GSM, ADPCM, Speex, T.38</center> | + | | <center><b>Voice and FAX codecs</b></center> || <center>G.711 A-law/U-law, G.722, G.729, GSM, ADPCM, Speex, T.38</center> |
|- | |- | ||
− | | <center><b>Video codecs</b></center> || <center>H.263, H.263+</center> | + | | <center><b>Video codecs</b></center> || <center>H.263, H.263+, H.264, H.265</center> |
|- | |- | ||
!{{Hl1}} colspan="2"|<div align="left"><b>Signalling/Protocols</b> | !{{Hl1}} colspan="2"|<div align="left"><b>Signalling/Protocols</b> | ||
Line 102: | Line 102: | ||
| <center><b>Powering</b></center> || <center>~230V±10%, 50Hz, 1A</center> | | <center><b>Powering</b></center> || <center>~230V±10%, 50Hz, 1A</center> | ||
|- | |- | ||
− | | <center><b>Dimensions</b></center> || <center>67mm(H) x 482(W) x | + | | <center><b>Dimensions</b></center> || <center>67mm(H) x 482(W) x 360mm(D)</center> |
|- | |- | ||
| <center><b>Work environment</b></center> || <center>Work temperature: +10˚C÷30˚C Air humidity: 40÷70%</center> | | <center><b>Work environment</b></center> || <center>Work temperature: +10˚C÷30˚C Air humidity: 40÷70%</center> | ||
|- | |- | ||
|} | |} | ||
− | |||
=NCP Gateways= | =NCP Gateways= | ||
Line 154: | Line 153: | ||
|- | |- | ||
| <center><b>NCP-GWS6S</b></center> || | | <center><b>NCP-GWS6S</b></center> || | ||
− | RACK SHELF-1U housing - depth | + | RACK SHELF-1U housing - depth 320mm<br> |
Capacity of max 48 equipment, brought on '''24''' terminals<br> | Capacity of max 48 equipment, brought on '''24''' terminals<br> | ||
Mainboard NCP-SP6BP.GWS (6 slots for EMS cards)<br> | Mainboard NCP-SP6BP.GWS (6 slots for EMS cards)<br> | ||
Line 161: | Line 160: | ||
|- | |- | ||
| <center><b>NCP-GWD6S</b></center> || | | <center><b>NCP-GWD6S</b></center> || | ||
− | RACK SHELF-1U housing - depth | + | RACK SHELF-1U housing - depth 320mm<br> |
Capacity of max 48 equipment, brought on '''48''' terminals<br> | Capacity of max 48 equipment, brought on '''48''' terminals<br> | ||
Mainboard NCP-SP6BP.GWS (6 slots for EMD cards)<br> | Mainboard NCP-SP6BP.GWS (6 slots for EMD cards)<br> | ||
Line 173: | Line 172: | ||
!{{Hl1}}|<center><b>Switch</b></center> !!{{Hl1}}|<center><b>Opis</b></center> !!{{Hl1}}|<center><b>Widok poglądowy</b></center> | !{{Hl1}}|<center><b>Switch</b></center> !!{{Hl1}}|<center><b>Opis</b></center> !!{{Hl1}}|<center><b>Widok poglądowy</b></center> | ||
|- | |- | ||
− | | <center><b>NCP-SWS24S</b></center> || | + | | <center><b>NCP-SWS24S <br> NCP-SW242S.P150</b></center> || |
− | RACK SHELF-1U housing - depth | + | RACK SHELF-1U housing - depth 320mm<br> |
+ | NCP-SW242S -26-port switch with layer 3 elements - without PoE and emergency power supply<br> | ||
+ | NCP-SW242S.P150 -- 26-port switch with layer 3 elements - 24 PoE ports and emergency power supply<br> | ||
Connecting up to 24 NCP-GWS/GWD Gateways and NCP-CMx Call Manager<br> | Connecting up to 24 NCP-GWS/GWD Gateways and NCP-CMx Call Manager<br> | ||
Features: 2xGbE; 24xEth; Power230Vac | Features: 2xGbE; 24xEth; Power230Vac | ||
− | || [[Image: | + | || [[Image:SW242S.jpg|300px]] |
|-<!-- | |-<!-- | ||
| <center><b>NCP-SWS24S.PoE</b></center> || | | <center><b>NCP-SWS24S.PoE</b></center> || | ||
− | RACK SHELF-1U housing - depth | + | RACK SHELF-1U housing - depth 320mm<br> |
Connecting up to 24 NCP-GWS/GWD Gateways and NCP-CMx Call Manager<br> | Connecting up to 24 NCP-GWS/GWD Gateways and NCP-CMx Call Manager<br> | ||
Features: 2xGbE; 24xEth; Power230Vac | Features: 2xGbE; 24xEth; Power230Vac |
Latest revision as of 09:34, 14 September 2022
Contents
NCP Call Manager
Network Centric PBX is consisted of one (or two in case of redundancy system) Call Manager NCP-CM, connected to it Gateways NCP-GW and system capacity expanding Switch - NCP-SW shelves.
Call Manager alone is a fully working PBX, in which we can configure IP terminals, IP providers and all services. To use TDM equippment, additional GWS (24 ports) or GWD (48 ports) with expansion modulesare required.
NCP-PBX can cooperate with maximum three independent networks via LAN, INT ar WAN interfaces (depending on CM type).
Available Call Manager solutions:
NCP-CM300P.BC low traffic support |
FUNCTIONAL FEATURES:
HARDWARE FEATURES:
|
|
average traffic support |
FUNCTIONAL FEATURES:
HARDWARE FEATURES:
|
|
heavy traffic support |
CECHY FUNKCJONALNE:
HARDWARE FEATURES:
|
Terminals
| |
---|---|
|
|
|
|
|
|
Voice/Video
| |
|
|
|
|
Signalling/Protocols
| |
|
|
|
|
|
|
|
|
|
|
Security
| |
|
|
|
|
Physical
| |
|
|
|
|
|
|
NCP Gateways
If traditional TDM equipment needs to be handled, NCP-GW (Gateways) with possibility to install modules are required.
Characteristic features of NCP-GWx:
- NCP Gateways (NCP-GWS/GWD) are connected to Call Manager with INT network interface
- Shelves use protocols: DHCP, NFS, TCP/IP, ETH
- GWx Gateways can be connected do INT interface directly or with usage of any L2 switches (within INT network). Network requires <2,5ms jitter.
- We do not reccomend to connect NCP-GWS/GWS via VPN tunnels.
Specified system services are configured in network, that they are available. NCP-GW cooperates with:
- internally
- via IP-LAN with SIP-VoIP terminals, SIP-Video, CTS.IP and NCP-GW
- via POTS-FXS ports with analog phones
- via CTS-Up0 ports with Slican CTS system phones
- externally
- via IP-WAN with SIP trunks
- via POTS-FXO ports with analog trunks
- via ISDN-BRI ports with ISDN-S(2B+D) trunks
- via ISDN-E1 with ISDN-E1(30B+D)
- via GSM ports with mobile trunks
Available Gateway solutions:
GWx2B and GWx6S
Gateways, allowing to use any modules.