Difference between revisions of "Installation Elements"

From pubWiki-en
Jump to: navigation, search
(Created page with "=Installation Elements= '''Patchpanel''', distribution panel, switchboard - passive elements of structured cabling used to organize space in ICT cabinets in RACK version. On f...")
 
 
(One intermediate revision by the same user not shown)
Line 2: Line 2:
 
'''Patchpanel''', distribution panel, switchboard - passive elements of structured cabling used to organize space in ICT cabinets in RACK version. On front side, it has set of 48 RJ-45 sockets on 19-inch wide metal strip, to which cables from other devices or telephone network are connected.  On inside, depending on model, it has RJ45 sockets or LSA connectors. Termination (crossover) of cables on LSA connectors is done with use of patch knives, which place one of stranded wires in connector. Patch panels are most often useful where large number of cables in star topology converge in one place.
 
'''Patchpanel''', distribution panel, switchboard - passive elements of structured cabling used to organize space in ICT cabinets in RACK version. On front side, it has set of 48 RJ-45 sockets on 19-inch wide metal strip, to which cables from other devices or telephone network are connected.  On inside, depending on model, it has RJ45 sockets or LSA connectors. Termination (crossover) of cables on LSA connectors is done with use of patch knives, which place one of stranded wires in connector. Patch panels are most often useful where large number of cables in star topology converge in one place.
  
'''Cable mounting shelf''' - element used to organize space in RACK version telecommunication cabinets. It allows to organize, segregate and fix telephone cables.
+
'''Cable mounting shelf''' - element used to organize space in RACK version telecommunication cabinets. It allows to organize, segregate and connect telephone cables.
  
'''Blanking plate for free spaces''' - element that complements free spaces between devices in RACK cabinet
+
'''Blanking panel for free spaces''' - element that complements free spaces between devices in RACK cabinet
  
 
=Patchpanel types=
 
=Patchpanel types=
 
==Patchpanel PPS.48RJ/48LSA==
 
==Patchpanel PPS.48RJ/48LSA==
 
===PPS.48RJ/48LSA.1U-BK===
 
===PPS.48RJ/48LSA.1U-BK===
<center>[[Plik:Panel krosowy PPS-48RJ-48LSA.1U-BK.jpg|700px]]</center>
+
<center>[[File:Patchpanel PPS-48RJ-48LSA.1U-BK.jpg|700px]]</center>
<center>Patchpanel 1U cat.3 - connecting 48 RJ45 sockets (only middle pair is connected in each) to 48 pairs for LSA connectors</center>
+
<center>Universal patchpanel 1U cat.3 - connecting 48 RJ45 sockets (only middle pair is used) to 48 pairs for LSA connectors</center>
  
 
===PPS.48RJ/48LSA.1U-DG===
 
===PPS.48RJ/48LSA.1U-DG===
<center>[[Plik:Panel krosowy PPS.48RJ48LSA.1U-DG.jpg|700px]]</center>
+
<center>[[File:Patchpanel PPS.48RJ-48LSA.1U-DG.jpg|700px]]</center>
<center>Patchpanel 1U kat.3 for NCP PBX - connectting 48 RJ45 sockets (only middle pair is connected in each) to 48 pairs for LSA connectors</center>
+
<center>Patchpanel 1U cat.3 for NCP PBX - connectting 48 RJ45 sockets (only middle pair is used) to 48 pairs for LSA connectors</center>
  
 
<b>Example application</b>
 
<b>Example application</b>
Line 23: Line 23:
 
==Patchpanel PPS.48RJ/12RJ==
 
==Patchpanel PPS.48RJ/12RJ==
 
===PPS.48RJ/12RJ.1U-BK===
 
===PPS.48RJ/12RJ.1U-BK===
<center>[[Plik:Panel krosowy PPS-48RJ-12RJ.1U-BK.jpg|700px]]</center>
+
<center>[[File:Patchpanel PPS-48RJ-12RJ.1U-BK.jpg|700px]]</center>
<center>Patchpanel 1U kat.3 - connecting 48 RJ45 sockets (w każdym podłączona tylko środkowa para) na 12 gniazd RJ45 (podłączone 4 pary)</center>
+
<center>Universal patchpanel 1U cat.3 - connecting 48 RJ45 sockets from front panel (only middle pair is used) to 12 sockets RJ45 inside (4 pairs from 4 next RJ 45 sockets front panel are connected)</center>
  
 
===PPS.48RJ/12RJ.1U-DG===
 
===PPS.48RJ/12RJ.1U-DG===
<center>[[Plik:Panel krosowy PPS.48RJ12RJ.1U-DG.jpg|700px]]</center>
+
<center>[[File:Patchpanel PPS.48RJ-12RJ.1U-DG.jpg|700px]]</center>
<center>Patchpanel 1U kat.3 dla central NCP - connecting 48 RJ45 sockets (w każdym podłączona tylko środkowa para) na 12 gniazd RJ45 (podłączone 4 pary)</center>
+
<center>Patchpanel 1U cat.3 for NCP PBX - connecting 48 RJ45 sockets from front panel (only middle pair is used) to 12 sockets RJ45 inside (4 pairs from 4 next RJ 45 sockets front panel are connected)</center>
  
 
<b>Example application</b>
 
<b>Example application</b>
* podłączenie central wykorzystujących karty ze specjalnym systemem wyprowadzeń 4 portów z jednego gniazda RJ-45 (IPL, IPM, NCP - karty abonenckie portów analogowych i systemowych, karty hybrydowe abonentów analogowych i linii miejskich analogowych) z wykorzystaniem minimalnej liczby kabli UTP - 12 zamiast 48szt.
+
* connection of PBX exchanges using cards with special system of 4 ports outputs from one RJ-45 socket (IPL, IPM, NCP - FXS cards and CTS ports, hybrid cards of FXS subscribers and FXO trunks) using minimum number of UTP cables - 12 instead of 48 pcs.
  
 
==Patchpanel PPS.48RJ/192LSA==
 
==Patchpanel PPS.48RJ/192LSA==
 
===PPS.48RJ/192LSA.1U-BK===
 
===PPS.48RJ/192LSA.1U-BK===
<center>[[Plik:Panel krosowy PPS-48RJ-192LSA.1U-BK.jpg|700px]]</center>
+
<center>[[File:Patchpanel PPS-48RJ-192LSA.1U-BK.jpg|700px]]</center>
<center>Universal patchpanel 1U kat.3 - connecting 48 RJ45 sockets (w każdym podłączone 4 pary) na 192 pary łączówki LSA</center>
+
<center>Universal patchpanel 1U cat.3 - connecting 48 RJ45 sockets on front panel (4 pairs connected in each) to 192 pairs for LSA connectors inside</center>
 
+
  
 
<b>Example application</b>
 
<b>Example application</b>
* zakończenie sieci telefonicznej na panelu krosowym LSA z wykorzystaniem wszystkich 4 par kabla UTP i wyprowadzenie jej na złączach RJ-45
+
* termination of telephone network on LSA connectors using all 4 pairs of UTP cable and its output on RJ-45 sockets on front panel
* wprowadzenie do sieci telefonicznej przez złącza RJ-45 sygnałów z 4 portów centrali w celu maksymalnego wykorzystania wszystkich par 4 kabli telekomunikacyjnych (w tym UTP) w sieci klienta. Pozwala na wykorzystanie minimalnej liczby kabli UTP - 12 zamiast 48 sztuk przy pełnej zajętości. Centrale IPL, IPM, NCP - posiadają karty abonenckie analogowe i systemowe oraz karty hybrydowe abonentów i linii miejskich analogowych ze specjalnym systemem wyprowadzeń 4 portów z jednego gniazda RJ-45.
+
* introducing signals from 4 PBX ports to telephone network via RJ-45 sockets in order to maximize use of all 4 pairs of telecommunication cables (including UTP) in customer's network. Allows use of minimum number of UTP cables - 12 instead 48 pcs when fully occupied. IPL, IPM, NCP exchanges - have FXS and CTS subscriber cards as well as hybrid cards for FXS and FXO trunk with special system of 4 ports from one RJ-45 socket.
  
 
===PPS.48RJ/192LSA.1U-DG===
 
===PPS.48RJ/192LSA.1U-DG===
<center>[[Plik:Panel krosowy PPS.48RJ192LSA.1U-DG.jpg|700px]]</center>
+
<center>[[File:Patchpanel PPS.48RJ-192LSA.1U-DG.jpg|700px]]</center>
<center>Patchpanel 1U kat.3 dla central NCP - pozwalający na podłączenie abonentów z 4 półek GW</center>
+
<center>Patchpanel 1U cat.3 for NCP PBX - allowing to connect subscribers from 4 GW shelves</center>
  
 
<b>Example application</b>
 
<b>Example application</b>
* zakończenie sieci telefonicznej na panelu krosowym LSA i wyprowadzenie jej na 48 złączach RJ-45 (4 abonentów na porcie RJ-45)
+
* termination of telephone network on LSA connectors inside and its output on 48 RJ-45 socket on front panel (4 subscribers on RJ-45 port)
* wprowadzenie do sieci telefonicznej przez złącza RJ-45 sygnałów abonentów z 4 półek GW centrali NCP w celu maksymalnego wykorzystania zasobów panelu krosowego. Centrale NCP - posiadają karty abonenckie analogowe i systemowe ze specjalnym systemem wyprowadzeń 4 portów z jednego gniazda RJ-45. Pozwala to dla pojedynczej półki GW znacznie zredukować liczbę kabli na wprowadzenie wszystkich abonentów z GW do panelu krosowego z 48 na 12. Przy podłączeniu 4 półek GW wykorzystane zostają wszystkie złącza RJ-45 panelu krosowego i zostaną doprowadzone sygnały 192 abonentów na łączówki LSA.
+
* introducing into telephone network via RJ-45 sockets of subscriber signals from 4 GW shelves of NCP exchange in order to maximize use of patchpanel resources. NCP exchanges - have analog and system subscriber cards with special system of 4 ports outputs from one RJ-45 socket. This allows for single GW shelf to significantly reduce number of cables to patchpanel from 48 to 12 pcs. for introducing all GW subscribers. When 4 GW shelves are connected, all RJ-45 sockets of patchpanel are used and signals of 192 subscribers will be connected to LSA connectors.
  
==Cable clamping shelf CCS.1U==
+
=Cable clamping shelf CCS.1U=
 
===CCS.1U-BK===
 
===CCS.1U-BK===
<center>[[Plik:Półka mocowania kabli.jpg|700px]]</center>
+
<center>[[File:Cable clamping shelf CCS.1U-BK.jpg|700px]]</center>
<center>Shelf 1U 19" organizing cable runs</center>
+
<center>Universal shelf 1U 19" organizing cable runs</center>
  
 
===CCS.1U-DG===
 
===CCS.1U-DG===
<center>[[Plik:Półka mocowania kabli CCS.1U-DG.jpg|700px]]</center>
+
<center>[[File:Cable clamping shelf CCS.1U-DG.jpg|700px]]</center>
 
<center>Shelf 1U 19" for NCP PBX organizing cable runs</center>
 
<center>Shelf 1U 19" for NCP PBX organizing cable runs</center>
  
Line 67: Line 66:
 
width x depth x height: 19" x 180mm x 1U
 
width x depth x height: 19" x 180mm x 1U
  
==Blanker BNK.1U==
+
=Blanking panel BNK.1U=
 
===BNK.1U-BK===
 
===BNK.1U-BK===
<center>[[Plik:zaślepka 1U.jpg|700px]]</center>
+
<center>[[File:Blanking panel BNK.1U-BK.jpg|700px]]</center>
<center>1U 19" blanker to fill free spaces</center>
+
<center>Universal 1U 19" blanking panel to fill free spaces</center>
  
 
===BNK.1U-DG===
 
===BNK.1U-DG===
<center>[[Plik:Zaślepka BNK.1U-DG.jpg|700px]]</center>
+
<center>[[File:Blanking panel BNK.1U-DG.jpg|700px]]</center>
<center>1U 19" blanker for NCP PBX to fill free spaces</center>
+
<center>1U 19" blanking panel for NCP PBX to fill free spaces</center>
  
 
<b>Example application</b>
 
<b>Example application</b>
 
* allows to fill empty spaces between devices to ensure proper cooling circulation in RACK cabinet
 
* allows to fill empty spaces between devices to ensure proper cooling circulation in RACK cabinet

Latest revision as of 09:16, 9 December 2022

Installation Elements

Patchpanel, distribution panel, switchboard - passive elements of structured cabling used to organize space in ICT cabinets in RACK version. On front side, it has set of 48 RJ-45 sockets on 19-inch wide metal strip, to which cables from other devices or telephone network are connected. On inside, depending on model, it has RJ45 sockets or LSA connectors. Termination (crossover) of cables on LSA connectors is done with use of patch knives, which place one of stranded wires in connector. Patch panels are most often useful where large number of cables in star topology converge in one place.

Cable mounting shelf - element used to organize space in RACK version telecommunication cabinets. It allows to organize, segregate and connect telephone cables.

Blanking panel for free spaces - element that complements free spaces between devices in RACK cabinet

Patchpanel types

Patchpanel PPS.48RJ/48LSA

PPS.48RJ/48LSA.1U-BK

Patchpanel PPS-48RJ-48LSA.1U-BK.jpg
Universal patchpanel 1U cat.3 - connecting 48 RJ45 sockets (only middle pair is used) to 48 pairs for LSA connectors

PPS.48RJ/48LSA.1U-DG

Patchpanel PPS.48RJ-48LSA.1U-DG.jpg
Patchpanel 1U cat.3 for NCP PBX - connectting 48 RJ45 sockets (only middle pair is used) to 48 pairs for LSA connectors

Example application

  • from PBX side - output of PBX ports (np: with RJ-21 connectors, Amphenol, another manufacturer, NCP) from LSA connectors to RJ-45 connectors for 19" RACK cabinet
  • from phone network side - in 19" RACK cabinet termination of twisted-pair cables leading directly to telephone subscriber sockets

Patchpanels enable convenient connection of telephone network and PBX ports with RJ-45 connectors or two sections of telephone network terminated on patchpanels by means of patch cords

Patchpanel PPS.48RJ/12RJ

PPS.48RJ/12RJ.1U-BK

Patchpanel PPS-48RJ-12RJ.1U-BK.jpg
Universal patchpanel 1U cat.3 - connecting 48 RJ45 sockets from front panel (only middle pair is used) to 12 sockets RJ45 inside (4 pairs from 4 next RJ 45 sockets front panel are connected)

PPS.48RJ/12RJ.1U-DG

Patchpanel PPS.48RJ-12RJ.1U-DG.jpg
Patchpanel 1U cat.3 for NCP PBX - connecting 48 RJ45 sockets from front panel (only middle pair is used) to 12 sockets RJ45 inside (4 pairs from 4 next RJ 45 sockets front panel are connected)

Example application

  • connection of PBX exchanges using cards with special system of 4 ports outputs from one RJ-45 socket (IPL, IPM, NCP - FXS cards and CTS ports, hybrid cards of FXS subscribers and FXO trunks) using minimum number of UTP cables - 12 instead of 48 pcs.

Patchpanel PPS.48RJ/192LSA

PPS.48RJ/192LSA.1U-BK

Patchpanel PPS-48RJ-192LSA.1U-BK.jpg
Universal patchpanel 1U cat.3 - connecting 48 RJ45 sockets on front panel (4 pairs connected in each) to 192 pairs for LSA connectors inside

Example application

  • termination of telephone network on LSA connectors using all 4 pairs of UTP cable and its output on RJ-45 sockets on front panel
  • introducing signals from 4 PBX ports to telephone network via RJ-45 sockets in order to maximize use of all 4 pairs of telecommunication cables (including UTP) in customer's network. Allows use of minimum number of UTP cables - 12 instead 48 pcs when fully occupied. IPL, IPM, NCP exchanges - have FXS and CTS subscriber cards as well as hybrid cards for FXS and FXO trunk with special system of 4 ports from one RJ-45 socket.

PPS.48RJ/192LSA.1U-DG

Patchpanel PPS.48RJ-192LSA.1U-DG.jpg
Patchpanel 1U cat.3 for NCP PBX - allowing to connect subscribers from 4 GW shelves

Example application

  • termination of telephone network on LSA connectors inside and its output on 48 RJ-45 socket on front panel (4 subscribers on RJ-45 port)
  • introducing into telephone network via RJ-45 sockets of subscriber signals from 4 GW shelves of NCP exchange in order to maximize use of patchpanel resources. NCP exchanges - have analog and system subscriber cards with special system of 4 ports outputs from one RJ-45 socket. This allows for single GW shelf to significantly reduce number of cables to patchpanel from 48 to 12 pcs. for introducing all GW subscribers. When 4 GW shelves are connected, all RJ-45 sockets of patchpanel are used and signals of 192 subscribers will be connected to LSA connectors.

Cable clamping shelf CCS.1U

CCS.1U-BK

Cable clamping shelf CCS.1U-BK.jpg
Universal shelf 1U 19" organizing cable runs

CCS.1U-DG

Cable clamping shelf CCS.1U-DG.jpg
Shelf 1U 19" for NCP PBX organizing cable runs

Example application

  • allows for convenient cable routing between devices in RACK cabinet
  • allows to keep right distance between devices to ensure proper cooling circulation

Dimensions of patch panels and cable mounting shelves

width x depth x height: 19" x 180mm x 1U

Blanking panel BNK.1U

BNK.1U-BK

Blanking panel BNK.1U-BK.jpg
Universal 1U 19" blanking panel to fill free spaces

BNK.1U-DG

Blanking panel BNK.1U-DG.jpg
1U 19" blanking panel for NCP PBX to fill free spaces

Example application

  • allows to fill empty spaces between devices to ensure proper cooling circulation in RACK cabinet