Doorphone assembly and installation should be executed by authotized person. It assures proper doorphone operating and validity of manufacturer guarantee obligations - otherwise, doorphone operating cannot be subject of guarantee claims. Assembly elements of DPH doorphone, located on back side are presented on following figure.
+
As mentioned above, DPH doorphone is suitable for under- and over-plaster assembly. On following figure, you can see the backside of DPH doorphone casing.
<center>[[File:DPH tyl oznaczenia.png]]</center><br>
+
<center>[[File:DPH tyl oznaczenia.png|200px]]</center><br>
Digits located on above figure indicated elements which are important while doorphone assembly:
+
Digit 1 - on above figure - indicate embossing, which can be cutted and after it create four holes for screwing doorphone casing to wall or pillar, where it should be assembled. Assembly can be done using appropriate screws &Phi;6, not included in doorphone set.
# Embossing on doorphone back side, which enable over-plaser assembly.
+
Over-plaster assembly is not recommended if doorphone is located on wall or pillar outside the building. In this stituation it is recommended to use special protection casing made of aluminium and protecting doorphone against results of rain- and snow-fall. This casing - it is separate position in price list - is sold with three screws for plastic 3,1x13, which enable to fix this casing to doorphone backside. Shape and dimensions of this casing are presented in chapter [[Characteristic of Slican DPH doorphones|2.1 Characteristic of Slican DPH doorphones]]. Fixing of protection casing to doorphone backside can be make using included screws and holes indicated with digit 2 on above figure. Every time during DPH doorphone assembly, before screwing all screws, connecting cables should be bring into the casing via hole indicated with digit 3. Except two mentioned above over-plaster assembly methods, under-plaster assembly is also possible. For under-plaster assembly special aluminium covering frame should be used, this frame is available in Slican offer. Under-plaster DPH doorphone assembly method is presented on following figure:
# Holes for screw down the external elements to doorphone back side - protection casing while over-plaster or under-plaster assembly, plates for assembly on fence.
+
<center>[[File:DPH pod tynk.png|300px]]</center>
# Holes for connection cables.
+
In this situation backside of DPH doorphone is screwed to the bacside of the wall niche. Symilarly as for over-plaster assembly before screwing all screws, connecting cables should be bring into the casing via hole indicated with digit 3. Under-plaster assembly is possible using special protection casing. Special protection casing is linked with DPH doorphone casing identically as for over-plaster casing. Assembly method is presented on following figure:
Elements visible on above screeen and don't indicated by digits are only important from technological point of view - the have no meaning during doorphone assembly and installation.
+
<center>[[File:DPH pod na tynk.png|400px]]</center>

Revision as of 12:41, 7 July 2017

As mentioned above, DPH doorphone is suitable for under- and over-plaster assembly. On following figure, you can see the backside of DPH doorphone casing.

DPH tyl oznaczenia.png

Digit 1 - on above figure - indicate embossing, which can be cutted and after it create four holes for screwing doorphone casing to wall or pillar, where it should be assembled. Assembly can be done using appropriate screws Φ6, not included in doorphone set. Over-plaster assembly is not recommended if doorphone is located on wall or pillar outside the building. In this stituation it is recommended to use special protection casing made of aluminium and protecting doorphone against results of rain- and snow-fall. This casing - it is separate position in price list - is sold with three screws for plastic 3,1x13, which enable to fix this casing to doorphone backside. Shape and dimensions of this casing are presented in chapter 2.1 Characteristic of Slican DPH doorphones. Fixing of protection casing to doorphone backside can be make using included screws and holes indicated with digit 2 on above figure. Every time during DPH doorphone assembly, before screwing all screws, connecting cables should be bring into the casing via hole indicated with digit 3. Except two mentioned above over-plaster assembly methods, under-plaster assembly is also possible. For under-plaster assembly special aluminium covering frame should be used, this frame is available in Slican offer. Under-plaster DPH doorphone assembly method is presented on following figure:

DPH pod tynk.png

In this situation backside of DPH doorphone is screwed to the bacside of the wall niche. Symilarly as for over-plaster assembly before screwing all screws, connecting cables should be bring into the casing via hole indicated with digit 3. Under-plaster assembly is possible using special protection casing. Special protection casing is linked with DPH doorphone casing identically as for over-plaster casing. Assembly method is presented on following figure:

DPH pod na tynk.png