Difference between revisions of "DPH - Doorphone connection"
Line 1: | Line 1: | ||
Connecting doorphone can be executed via appropriate cables connected to connecting terminal located on doorphone PCB. Connecting terminal is visible and accessible afer unscrewing front panel, this operation is described in chapter [[DPH - Opening doorphone casing|2.2 DPH - Opening doorphone casing]]. | Connecting doorphone can be executed via appropriate cables connected to connecting terminal located on doorphone PCB. Connecting terminal is visible and accessible afer unscrewing front panel, this operation is described in chapter [[DPH - Opening doorphone casing|2.2 DPH - Opening doorphone casing]]. | ||
− | {{warning|Before connecting cables to connecting terminal, cables should be bring into the casing via hole located on casing backside.}} | + | |
− | Connections located in connection terminal | + | |
+ | {{warning| | ||
+ | Before connecting cables to connecting terminal, cables should be bring into the casing via hole located on casing backside.}} | ||
+ | |||
+ | |||
+ | =Connections located in connection terminal used to doorphone installation= | ||
<center> | <center> | ||
{|{{Prettytable}} | {|{{Prettytable}} | ||
Line 11: | Line 16: | ||
|LA | |LA | ||
|- | |- | ||
− | |EZ ||rowspan="2"| electrolock | + | |EZ ||rowspan="2"| electrolock power supply; program mode setting: NO (switching on voltage) - electromagnetic lock/NC (switching off voltage) – electromagnetic keeper; '''source voltage: 12V, max. source load: 0.7A''' |
|- | |- | ||
|EZ | |EZ | ||
|- | |- | ||
− | |STA ||rowspan="2"| isolated | + | |STA ||rowspan="2"| isolated relay contact (NO) for controlling additional devices; programming operating mode: Gate/Light; '''max: load contact 32V AC/DC 1A''' |
|- | |- | ||
|STA | |STA | ||
|- | |- | ||
− | |AC ||rowspan="2"| power supply connections 14 - | + | |AC ||rowspan="2"| power supply connections '''14 - 35V DC or 18 - 25V AC''' |
|- | |- | ||
|AC | |AC | ||
Line 25: | Line 30: | ||
|COD || opening door sensor - disconnection from GND decrease EZ relay operation time | |COD || opening door sensor - disconnection from GND decrease EZ relay operation time | ||
|- | |- | ||
− | |POD || | + | |POD || opening door button (relative to GND) |
|- | |- | ||
|GND || ground for POD, COD signals | |GND || ground for POD, COD signals | ||
|} | |} | ||
</center> | </center> | ||
− | Connection scheme of doorphone DPH | + | |
− | <center>[[File:Schemat podlaczenia DPH.png]]</center><br> | + | |
− | DPH doorphone supply can be realized using AC or DC. Power supply device should be selected according user needs. Due to wide possibilities, Slican company doesn't | + | =Connection scheme of doorphone DPH= |
+ | |||
+ | |||
+ | {{warning| | ||
+ | Automation control that requires a short circuit can be connected only to STA output}} | ||
+ | |||
+ | <center>[[File:Schemat podlaczenia DPH.png|800px]]</center><br> | ||
+ | |||
+ | |||
+ | {{warning| | ||
+ | Connecting live wires to EZ terminals may cause permanent damage to device}} | ||
+ | |||
+ | |||
+ | =Power supply= | ||
+ | DPH doorphone supply can be realized using AC or DC. Power supply device should be selected according user needs. Due to wide possibilities, Slican company doesn't sell power supply device together with DPH doorphone, it remain to user decision. In Slican offer - as a separate position in price list - there is AC transformer TRS10-V18-N, with nominal voltage equal to 18V, this transformer fulfil supply requirements of DPH doorphone. Below is presented mentioned above transformer: | ||
+ | |||
+ | |||
<center> [[File:Trafo TRS10-V18-N.png]]</center> | <center> [[File:Trafo TRS10-V18-N.png]]</center> |
Latest revision as of 06:52, 2 June 2020
Connecting doorphone can be executed via appropriate cables connected to connecting terminal located on doorphone PCB. Connecting terminal is visible and accessible afer unscrewing front panel, this operation is described in chapter 2.2 DPH - Opening doorphone casing.
|
Connections located in connection terminal used to doorphone installation
Connection scheme of doorphone DPH
|
|
Power supply
DPH doorphone supply can be realized using AC or DC. Power supply device should be selected according user needs. Due to wide possibilities, Slican company doesn't sell power supply device together with DPH doorphone, it remain to user decision. In Slican offer - as a separate position in price list - there is AC transformer TRS10-V18-N, with nominal voltage equal to 18V, this transformer fulfil supply requirements of DPH doorphone. Below is presented mentioned above transformer: