Introduction

Digital doorphone system Slican HAS-3000 and HAS-300T are modern, elegant and reliable solutions mainly for apartment buildings (multiflat – one cassette is used for one staircase), as well as for office biuldings.

Housing of doorphone cassette is performed using high quality materials, durable and resistible for wether circumstances. Due to safety requirements housing is mounted under-plaster.

System can be available in cassette KD12P - from thick sheet of stainless, lacquered with atomized powder steel with backlighted list of apartments and socket for touch memory (only in model HAS-3000T).

HAS-3032 Cassette.png
Figure 1: Elements of KD12P cassette

System cassette enables to utilize user and service functions. In cassette, legible and contrast LED display is included, as well as modern and durable touch capacitive keypad. This keypad assure precise and audio confirmed selection of every key. Backlighted keys enable to comfortable using kepad even in total darkness. Due to no metal contacts in kepad, long proper device working is guarated. Backlighted window for apartments list enable to show all needed information.

System connects with uniphones installed in apartments using 2-wires databus, it enable to adapt existing cable infrastructure. Additionally it enables to decrease costs of such wiring.

Due to using modern technologies doorphone system Slican HAS-3000 offers wide range of functions – below you can find most important system features:

  • system capacity: up to 255 apartments/uniphones,
  • dialing from cassette to uniphone/apartment,
  • establishing connection from uniphone to doorphone cassette,
  • connection of uniphone: 2-wires,
  • audio signal also by improperly hang-off uniphone handset,
  • possibility of connecting additional opening door button (ex. for front desk),
  • possibility of connecting additional, external button for uniphone selection,
  • coded lock function – opening door using access code (PIN),
  • 2 independent control output (door and gateway) – independent opening both exits from uniphone or cassette,
  • full errors detection (improper uniphone connection, umproperly programmed, etc.),
  • uniphone signal during coded (using PIN) door opening,
  • usetting PIN automaticaly/manually individually for every apartment,
  • power supply using save voltage 12VAC or 12VDC,
  • nominal power supply current 300mA,
  • working temperature -25 to +55°C,
  • adjusted, maximal number of ringing tone,
  • adjusted, maximal call duration time.

Assembly

Conditions of proper installation:

  • Power supply from source of AC current 230V, 50Hz, via external transformer.
  • Doorphone cassette should be mounted in appropriate place.
  • It is recommended to protect doorphone cassette against direct acting of sunshine and rain.
  • Cassette power supply device locate in place protected against humidity.
  • Due to safe reasons doorphone infrastructure mustn't be accessible by unathorized persons.
  • Uniphones are designed for work in vertical location.
  • Uniphones should be protected against humidity, steam and high termperature.

Dimensions of niche for KD12P cassette

Mentioned below dimensions are in mm:

  1. 1.Part to build in: hight 176,2; width 212,2; depth 34.
  2. 1.External dimensions on plaster (frame): hight 201; width 237.

Disassembly of cassette front panel

Unscrew two bolts from cassette front panel and next:

  1. Lift front panel about 30° from vertical and draw it up from the hinges (see pos. 1) - in this situation remove front panel.
  2. Lift front panel by 90° (see pos. 2) - in this situation front panel is locked – such position is helpful while connecting terminals or tuning.


HAS-3032 Assembly.png

Network installation

Doorphone databus - providing signal to premises (unophones) - consist of two wires. Polarity of these wires is crucial for proper system operation.

Because all uniphones are supplied by common wires, they should be good quality and fulfil following conditions:

  • resistance of databus loop should be less than 10Ω, which is adequate to 100m wires with 0,5mm2 of diameter,
  • to increase databus range, it is enough to:
    • connect in parallel wires in multi-wire cable or
    • use wires with greater diameter to perform databus.
HAS-3032 Uniphone bus.png
Doorphone system HAS-3000 databus

Description of terminals in Slican HAS-3000 and HAS-3000T cassette

Terminal
Description
Notes
LU+
Positive end of uniphone databus
Uniphone databus
LU-
Negative end of uniphone databus
Uniphone databus
POD
Opening door button (connected to the ground)
COD
Open door sensor (connected to the ground)
GND
Ground, ex. for connecting POD, COD, STA
STA
Auxilary output – gateway automatic control
Relay output
connected to the ground
max. load 1A/24VDC
+12V
DC output, circa 12-16V, to the GND
max. load 250mA
EZ
Electrolock
AC terminals connected via
relay 1A
EZ
Electrolock
AC terminals connected via
relay 1A
12AC
AC Power supply
12V~ ±3V
12AC
AC Power supply
12V~ ±3V
Jumpers
Description
PROG
Entering programming mode without password

Uniphones

Slican HAS-30XX systems can operate with digital uniphones of other manufacturers (Proel and Urmet uniphones were tested: they works properly but doesn't support full functionality of system Slican HAS-30XX) with address decoders.

In our offer there is specialized digital uniphone Slican US.P2W-HAS255 in gray colour, with two buttons, signaling LED diode and i ringer volume adjustment.

Details are included in Instruction manual for Slican US.P2W-HAS255.

Attention: Polarity of wires L-/L+ should be observed while connecting electronic board of uniphone. While incorrect connection of databus wires: LU- i LU+ to uniphone electronic board terminals, uniphone works incorrect.

Using Slican HAS-3000 and HAS-3000T system

Differences between doorphone system HAS-3000 and HAS-3000T

In below table listed are functions which are different in system HAS-3000 and HAS-3000T.

Function
HAS-3000
HAS-3000T
Opening door using touch memory
-
+
"Free access" function
+
+

Calling apartment (uniphone) from doorphone cassette – establishing call to specified apartment

Most frequently used doorphone function is call from doorphone cassette to apartment (uniphone). Below you can find method of do it:

  • On doorphone keypad dial apartment number to establish call (if dialed number doesn't exist in doorphone system uniphones or uniphone in this apartment is not connected, caption OFF appears on display), next wait for answering call (lifting handset is signal by CALL caption on display).
    ATTENTION! Pauses between digits while apartment number dialing, cann't be longer than 3 seconds. Otherwise system assumes that, apartment number dialing was finished.
  • If somebody open the door on display caption OPEn can be seen.
  • Number of ringing can be adjusted from 2 to 8 ringings. After finishing audio signaling door can be open from apartment during about 30 seconds. For long calls finishing time is signal by series of 10 beeps with decreasing volume level.
  • In any time it is possible to cancel dialing or uniphone signaling by pressing C key.
  • Door can be open using one of two methods:
  1. During dialing, without lifting handset, or during 30 secons time after finishing call, by presing opening button.
  2. After lifting handset and conversation with doorpne cassette by pressing opening button.

Calling wrong hang-off uniphone

After detecting wrong hang-off uniphone handset, ringing procedure is symilar as if uniphone handset is hang-of correctly with following differences:

  1. ringing signal is changed,
  2. lifting handset of such ringing unipone is possible during ringing pauses and during following 30 seconds waiting time,
  3. answering call to uniphone is possible by shortly press the uniphone hook.

1.1 Dialing doorphone cassette from uniphone

Procedure of establishing call from uniphone to doorphone cassette is following:

  1. Lift the handset.
  2. Press the opening door button.
  3. After „beep” signal in handset, press any button once more.
  4. Call is established.

During call it is possible to:

  • open door (button with key-sign),
  • gateway (second uniphone button).

Call is disconnected after hang-off the handset or after pressing C key on keypad.
ATTENTION! Maximal time of call from uniphone to doorphone cassette is limited to 30 seconds (function is available after 45 seconds after switching on power supply).

Opening gateway from uniphone

It is possible to open gateway using uniphone – this function is supported only by two-buttons digital Slican uniphones and can be realized using second opening button.

Opening door without establishing call

It is possible to open door when the call is not established. To do this you should lift handset and two times quickly (with pause no longer than second) press open door button.
ATTENTION! This function is active, if no call is established.

Opening door using PIN code

Procedure of opening door is following:

  1. Dial apartment number – on LED display dialed digits are visible.
  2. Accept:
    * pressing button IioHAS 3000 Kluczyk.JPG - for opening door,
    * pressing 2-times button IioHAS 3000 Kluczyk.JPG - for opening gateway.
  3. Dial PIN code – on LED display symbols instead of digits are visible, it make impossible to read PIN code.
  4. On display caption OPEn appears, as a signal of opening electrolock.

Opening door without PIN-code ("Free access" function)

Doorphone systems HAS-3000 and HAS-3000T include "Free access" function. This function is specially useful for public access location which is located in building protected by doorphone system ex. surgery. If such apartment is defined as public access location (option P3.2/L2.2 - see chapter HAS-3000 and HAS-3000T system programing), after lifting uniphone handset in this apartment, dialing number of this apartment on doorphone keyboard results with door opening. For uniphone handset on hook, standard ringing procedure is realized and answering call is obligatory before opening door before opening door. If apartment is not defined as public access location, after dialing apartment number from doorphone keyboard procedure of calling wrong hang-off uniphone is realized (see chapter Calling wrong hang-off uniphone).

1.1 Changing PIN code from doorphone keypad

It is possible to change premise PIN code using keypad. Procedure is following:

  1. Dial apartment number – on LED display dialed numbers are visible.
  2. Accept dialing by pressing three times IioHAS 3000 Kluczyk.JPG button. Flashing lines will be displayed.
  3. Select old PIN number and accept it by IioHAS 3000 Kluczyk.JPG button.
  4. Select new PIN and accept it by IioHAS 3000 Kluczyk.JPG button.
  5. To check propriety of selected PIN once more and once more accept it by IioHAS 3000 Kluczyk.JPG button. If changing PIN procedure was performed properly, single line moves across the display.
  6. After finishing PIN edition new value is already active.
Shortly:
IioHAS 3000 Kluczyk.JPGIioHAS 3000 Kluczyk.JPGIioHAS 3000 Kluczyk.JPG[old PIN]IioHAS 3000 Kluczyk.JPG[new PIN]IioHAS 3000 Kluczyk.JPG[new PIN]IioHAS 3000 Kluczyk.JPG

Opening door sensor - COD

This sensor is used to immediate switch off electrolock after detecting door opening.

Closed - it is default mode of electrolock (NC) – when active electrolock is open. This terminal can be also configured to dialing specified apartment (See programming table: Admin level).

Opening door button - POD

Is used for immediate opening door – by short connection to the ground, without using uniphone. This terminal can be also configured to dialing specified apartment (See programming table: Admin level).

"Free access" function programing

To define specified apartment as free access location, which could open door directly from doorphone keyboard without entering PIN code it is necessarily to execute following operation:

  1. To enter programing mode, press IioHAS 3000 Kluczyk.JPG and next enter admin code (by default 1234),
  2. Caption "P-" will be visible on display,
  3. Pressing button 2 or 8 set P3 on display,
  4. Press button 6 to select this option. Caption "Pin" will be visible on display,
  5. After next pressing button 6, caption on display changes to "LED",
  6. Accept selected option by IioHAS 3000 Kluczyk.JPG button,
  7. Na wyświetlaczu migają cztery kreski ----. W tym stanie wprowadzamy numer lokalu i naciskamy klawisz IioHAS 3000 Kluczyk.JPG,
  8. Na wyświetlaczu pojawi się napis L1. Naciskając klawisz 8 zmieniamy go na L2,
  9. Po dwukrotnym naciśnięciu klawisza 6 na wyświetlaczu pojawi się napis 'on' lub 'off', zależnie od tego czy dany lokal jest już zdefiniowany jako gabinet,
  10. Naciskamy klawisz IioHAS 3000 Kluczyk.JPG. Kolejne naciskanie klawisza 8 powoduje zmianę stanu na przeciwny (włączenie lub wyłączenie funkcji gabinet dla danego lokalu),
  11. Po wybraniu właściwej opcji naciskamy klawisz IioHAS 3000 Kluczyk.JPG, zatwierdzając dokonany wybór.

Jeżeli lokal zostanie zdefiniowany jako gabinet, to po podniesieniu słuchawki unifonu, wybranie numeru lokalu na klawiaturze spowoduje otwarcie drzwi. Przy odwieszonej słuchawce domofonu wybranie numeru lokalu na klawiaturze powoduje dzwonienie unifonu.

Safety requirements while using digital doorphone system HAS-3000

Security rules and proper using must be obligatory observed for assuring device proper operation.

Below basic rules concerning doorphones are presented. Without fulfiling these rules any claim or notice presented by users cann't be accepted by manufacturer. Rules presented here concerns installation, premises and requirements concerning power supply network.

Installation of HAS-3000

  • All installation activities should be performed according OSH.

Scheme for creating description label

Working environment of HAS-3000

  • Device should not be installed inside buildings or spaces with high humidity due to durability and operation of electrical elements. Doorphone housing is resistant on wether circumstances, but when installed otside building it is recommended to install in sheltered places to avoid rain and wind, wich can disturb conversation from doorphone.
  • Due to risk of flood of water, device should not be located near water reserviors (pools, taps, etc.).
  • Doorphone should not be installed in premises with high dustiness or electromagnetic field intensity.

It is strictly forbidden to instal doorphone in following permises:

  • in premises with direct influence of solar light,
  • in premises where wibration are very often or strong,
  • near radio aerials (especially for short waves).

Electrical requirements

  • Device should have proper earthing.
  • All devices connected to doorphone should have certificates of conformity with EU regulations.

Summary

We thank You very much for purchasing Slican product. Our company will do all the best to fulfil Your expectations concerning purchased product, so please inform us about Your ideas concerning improve product.

If this manual doesn't fulfil Your expectations, please send us information what chapters should be added or extended.

We wish You a nice and problemless doorphone using.

Proper equipement disposal

Disposal.jpg