DPH - Doorphone programming

From pubWiki-en
Revision as of 08:05, 18 October 2011 by Grzegorzg (Talk | contribs) (Summary)

Jump to: navigation, search

Establishing call

  • To program DPH doorphone it is necessarily to establish call between PBX phone and doorphone.
  • Doorphone is programmed using DTMF tones send by phone connected to doorphone.

Programing mode entering: 0987

  • To enter programing mode - during established call dial: 0987
  • In programing mode:
    • doorphone buttons don't operate and after pressing any button reject signal (low frequency) is generated.
    • Loudspeaker is muted.

Navigation

*(asterisk) Cancel

  • After pressing *, in every moment, entered parameter is canceled and program returns to XY coordinates selection.

# (hash)OK Confirm

  • After pressing # entered parameter is confirmed.
  • After pressing # doorphone answers as follows:
    • confirmation signal (high frequency)
    • rejest signal (low frequency) if entered parameter is improper.

Leaving programing mode 2 x * (asterisk)

  • After pressing asterisk two times program mode is leaving.
Warning! Entering program mode is possible if jumper SETUP is ON.


Programming table

  • Values in [ ] - default values
  • All programable gfields are organized as XY coordinates table.

DPH programming table is as follow

Y\X 0 1 2 3 4 Meaning
1 Short number 0
Top button
[21]
Short number 1
Bottom button [empty]

Number dialed after pressing button.

Max 16 digits No number - button disabled

2 Number dialing finish with #(Hash) [1]
1 - ON
0 - OFF
Only handset lifting [ ]

Line occupation. In PBX hot line must be declared.
0-Top button
1-Bottom button
Empty - hot line is inactive

Max call time [180]

10..360 sec

Not operated DPH factory settings

# confirm, after confirmation DPH resets

Settings

3 EZ opening time [3] 1..60 sec EZ working mode [0]

0 - electrolock (NO)
1 - electromagnetic keeper (NC)

STA opening time [2]

1..60 sec

Receiving DTMF * [3]

0 - no action
1 - EZ opening
2 - STA opening
3 - EZ and STA opening at the same time

User RFID action [3]

0 - no action
1 - EZ opening
2 - STA opening
3 - EZ and STA opening at the same time

Output settings

  • EZ - electrolock,
  • STA - automatic control
4 Speaker volume [3]
Allowable values 0..7,
0 - minimal volume
Speaker volume change
2 - increase volume
8 - decrease volume

During adjustment DPH speaker is active

Speaker sensitivity [1]

0 - small
1 - medium
2 - high

Acoustic settings

5 Service RFID card 0000 - store service card
Service card enables to
assign new RFID cards.
Remove RFID cards
0000- remove all RFID cards

RFID cards

Summary

  • XY coordinates acceptation causes high frquency (OK) signal generation.
  • It is possible to entering XY coordinates longer than 2 digits - only two last digits will be used.
  • XY coordinates confirmation - button HASH (#)
  • Parameter entering can be always canceled by STAR (*) button. as a result low frequency signal (BAD) is generated and jump to coordinates selecting
  • Confirmation of any parameter can be done with HASH (#) button. If parameter value is correct and parameterr was succesfully stored in FLASH memory - high frequency signal (OK) is generated and dorphone waits for coordinates selection.
  • If parameter value is incorrect - low frequency signal (BAD) is generated and dorphone waits for coordinates selection.
  • Max call time - new value is obvious for next call
  • For DPH.AB-KS1 short number 0 is active
  • For DPH.AB-KS2 short numbers 0 (upper button) and 1 (lower button) are active
  • For DPH.AB-KS1,2RF field 05 is active (RFID cards)

Back